ELECTRICAL CONNECTION 

Before connecting the PHENIX to the mains, it is essential to check the power 
protection using a 30mA differential device. 
The power supply must be permanent and properly protected against any possible 
overvoltage and overloads. 

 

Installing PHENIX with a CCEI LIMPIDO chlorinator: 
The PHENIX fits, in series, between the flow detector (supplied with the LIMPIDO) 
and the LIMPIDO. 
Connect the LIMPIDO flow detector to the PHENIX “Flow detector” input (under the 
cabinet on the left). 
Connect  the  control  cable  supplied  with  the  PHENIX  between  the  PHENIX  control 
output (under the cabinet, on the right) and the LIMPIDO “Flow detector” input 

 

Limpido WITHOUT PHENIX 

Limpido WITH PHENIX 

 

 
 
 
 

The power supply must be permanent and properly protected against any possible 
overvoltage and overloads. 

LIMPIDO 
flow 
detector 

LIMPIDO 
chlorinator 

Flow detector 
supplied

 

with 

the LIMPIDO

 

Control cable supplied with the 
Phenix (cut into 2 identical 
parts: one for the input and the 
other for the output

 

Содержание PF10J025

Страница 1: ...TECHNICAL CHARACTERISTICS 2 OVERVIEW 3 pH 3 Redox 3 OPERATION 4 Display 4 pH Menu 6 Oxidant Menu 8 Settings Menu 9 HYDRAULIC CONNECTION 10 Installing the sensors 10 Installing the injector 10 Installa...

Страница 2: ...de to 650mV Accessories supplied 4 m of crystal tube 3 x Sockets in 50 mm 1 Suction strainer for pH corrector 1 x Injector 1 x pH7 Calibration solution 1 x pH9 Calibration solution 1 x 650mV Calibrati...

Страница 3: ...e salt chlorinator causes an increase in pH which makes pH regulation particularly useful PHENIX maintains the pH of your pool by injecting a pH correcting solution into the water as required The user...

Страница 4: ...l is shown on the left in mV1 A P appears if the chlorinator is asked to produce chlorine then an arrow indicates if filtration is operational The measured pH 1 is then displayed Messages in the syste...

Страница 5: ...since the start of the 24 hour period When chlorine production is activated a P is displayed on the right of the screen The following three screens are only visible in Installer mode They allow acces...

Страница 6: ...mode can be used during wintering for example To validate the mode press the key To exit the programme without validating the mode press the key This screen is used to define the pH set point To chang...

Страница 7: ...iance is commissioned as stated in the Maintenance paragraph Calibration is carried out using the two solutions supplied with the PHENIX a PH7 solution and a PH9 solution To begin calibration press th...

Страница 8: ...ns dependent on the operation of the filtration pump OFF to prevent the chlorinator injecting any chlorine This mode can be used during wintering for example To validate the mode press the key To exit...

Страница 9: ...you access the various different PHENIX settings The and keys are used to scroll through this menu The different displays in this menu are This menu allows you to choose from 8 languages for the PHEN...

Страница 10: ...holder and sensor must be used All connections should be made with TEFLON INSTALLING THE SENSORS The sensors are used to measure the pH and ORP The electrodes which form part of the sensors generate a...

Страница 11: ...dle Pipe saddle to be positioned on the piping system INSTALLATION DIAGRAM The various parts of the PHENIX that must be positioned on the pool s piping system are The pH sensor must be positioned dire...

Страница 12: ...PIDO and the LIMPIDO Connect the LIMPIDO flow detector to the PHENIX Flow detector input under the cabinet on the left Connect the control cable supplied with the PHENIX between the PHENIX control out...

Страница 13: ...input under the cabinet on the left using one of the two cables obtained above Connect the control output of the PHENIX under the cabinet on the right to the Flow detector input of the LIMPIDO EZ usin...

Страница 14: ...tor input of the PHENIX under the cabinet on the left using one of the two cables obtained above Connect the control output of the PHENIX under the cabinet on the right to the RedOx Control input of t...

Страница 15: ...immediately sensors stored dry require rehydration for several hours but they will be less aged Consequently we recommend for long term storage store dry for short term storage in a trimolar KCl solu...

Страница 16: ...he appliance has been cleaned with a cleaning solution after a long period of storage if the measurements results differ too much from the expected results Date of sale Serial no Declaration The compa...

Отзывы: