5.0 Maintenance
5.1 Introduction
The
CBS ArcSafe®
RRS-2-BE is designed to require little maintenance; however, adopting a regular maintenance
program will keep the RRS-2-BE in good condition allowing years of trouble-free service.
5.2 Prior to Use
Before use examine the general condition of the unit.
1.
Inspect the switch and indicators for tightness and damage.
2.
Inspect the cables for wear or cracking, always replace a damaged cable.
3.
Check cable core grips for tightness.
4.
Check for loose fasteners.
5.
Ensure actuators are free of dirt and grime by wiping down with a dry cloth.
6.
Run the unit unloaded to verify there is no abnormal noise or vibration. If
abnormal condition exists, do not use.
5.3 After Use
After use, clean the RRS-2-BE ensuring the unit is free of dust and debris. Ensure the unit is free of oil or grease
and if necessary, clean with a dry cloth. Store the device covered with either the standard dust cover or the
waterproof cover (optional), in a clean, dry location to prevent damage.
5.4 Yearly Maintenance
Every twelve to eighteen months, depending on use,
CBS ArcSafe®
recommends performing the following
preventative maintenance.
1.
Check that the batteries maintain a charge.
2.
Perform an electrical inspection of internal wiring, checking for signs of heat and
loose connections.
3.
Check all cables for extreme wear or cracks.
4.
Check that the pneumatic tires (optional) are properly pressurized to 24 PSI and
sufficiently sealed.