RRS-2 Technical Manual 29
© 2010 CBS ArcSafe
®
2012-04-18
Appendix B: Troubleshooting Guide
Symptom
Problem
Solution
The system power will not
energize when the main power
switch is in the ON position.
The over-current protection
relay has tripped.
The emergency stop
pushbutton is latched.
The battery leads are
disconnected.
The batteries are completely
discharged.
An open circuit has occurred
within the sealed batteries.
Reset the over-current protection
relay within the electrical cabinet.
Rotate the emergency stop
pushbutton clockwise to reset.
Reconnect the battery terminal
leads.
Charge the system batteries.
Test and replace the system
batteries.
The system batteries will not
charge/will not hold a charge.
The battery leads are
disconnected.
The battery charger is not
connected to AC power.
Faulty batteries or charger.
The RRS-2 has been stored in
freezing temperatures.
The batteries have aged from
non-use.
The batteries are being stored
without a charge.
Reconnect the battery terminal
leads.
Check the AC power connection.
Replace faulty equipment. Contact
your CBS ArcSafe® Technical Sales/
Support Agent to obtain
replacement parts.
Contact your CBS ArcSafe®
Technical Sales/ Support Agent for
solutions.
Replace the system batteries. In
order to obtain the longest life out
of your batteries they must be
discharged regularly. Contact your
CBS ArcSafe® Technical Sales/
Support Agent to obtain
replacement parts.
Replace the system batteries.
Batteries must be charged before
the unit is stored. Contact your
CBS ArcSafe® Technical Sales/
Support Agent to obtain
replacement parts.
Содержание RRS-2
Страница 32: ...RRS 2 Technical Manual 28 2010 CBS ArcSafe 2012 04 18 This page has been intentionally left blank...
Страница 34: ...RRS 2 Technical Manual 30 2010 CBS ArcSafe 2012 04 18 This page has been intentionally left blank...
Страница 38: ...RRS 2 Technical Manual 34 2009 CBS ArcSafe 2012 04 18 This page has been intentionally left blank...
Страница 42: ...RRS 2 Technical Manual 38 2009 CBS ArcSafe 2012 04 18 This page has been intentionally left blank...