L1
L2/N
L2/N
120/240
V AC
120/240
V AC
OUTPUT 2
L1
L2/N
L2/N
ALARM
0-10V IN
LUX SENSOR
A
B
*** DLS02 Light Sensor
A White
B Green
+ Red
- Black
*** To extend the light sensor cable, use Belden 8723 type cable or equivalent
for RS-485 applications. It is recommended to weld the splices and cover them
with heat shrink tubing to make the connection waterproof.
* The connection of the alarm relay to an external alarm system must be done according
to the alarm system manufacturer’s recommandations.
MALT
0-10V Output
from Master
Controlelr **
** The master controller is only required if using the LUMIX in slave mode
Red lights on
Output 1
Blue lights on
Output 2
Connect the lights with the lowest K-Color value (ex: 2000K) on output 1
Connect the lights with the highest K-Color value (ex: 6000K) on output 2
* Alarm
Contact
WIRING DIAGRAM
OUTPUT 1