       Manual

Version 2.13e   Date: 12/2019

for firmware 2.13

Содержание AirLaser IP100plus

Страница 1: ...1 Manual Version 2 13e Date 12 2019 for firmware 2 13 ...

Страница 2: ...up 12 6 Operation 14 6 1 Discovery and IP address 14 7 Webmanagement 17 7 1 Login accounts and passwords 17 7 2 System 19 7 3 Network 20 7 4 Port control 21 7 5 Time Date 24 7 6 Services 25 7 7 Firmware 27 7 8 Config File 28 7 9 Reset 30 7 10 Tests 31 7 11 Status 33 7 12 Logfile 36 7 13 Port counter 37 7 14 History 38 7 15 Backup 39 7 16 Email 41 7 17 Remote Syslog 42 7 18 Quality Of Service 43 Ap...

Страница 3: ...kV power 1kV signal High power pulses following EN61000 4 5 2kV unsymmetrical 1kV symmetrical on power and data line RF on cables following EN61000 4 6 150kHz 80MHz 3V on power and data line Low frequent magnetic fields following EN61000 4 8 1A m Voltage reduction following EN61000 4 11 95 during 0 5 periods 30 during 25 periods 95 during 250 periods Overtons following EN61000 3 2 Flicker followin...

Страница 4: ...fety precautions Do not look into the connector When push or pull connectors switch AirLaser off Infrared laser radiation not visible Attention When cover open laser radiation class 3B will be emitted AirLaser is waterproof sealed Under the cover are no switches or indicators Warranty is void if cover was open Flash protection CBL recommends to connect the installation pole to protection ground Ai...

Страница 5: ...c cable or twisted pair cable TP with the LAN segments The terminals are waterproof and designed for outdoor mounting Each unit has transmitter receiver and a telescope for adjustment Front view of AirLaser IP1000plus In all 4 corners are the lenses of the four transmitters They emit the infrared radiation In the middle is the receiver lens Above that the telescope for adjustment Left and right ha...

Страница 6: ...e near or under the beam run Smoke absorbs the infrared light No outlets of warm air or water vapour should be near or under the beam rund Turbulences have influence to the infrared light Take care with air condition systems Trees or cranes can interrupt the beam Free access to the backpanel is necessary If possible use a location which is protected against unlimited wind rain snowfall and sun rad...

Страница 7: ...3 2 Cabeling Very simple is the connection of AirLaser IP1000plus via TP cable Note the maximum cable length If longer cable length are required connection is also possible with fiber optic cables 7 ...

Страница 8: ...l head horizontal Fix only one screw for the vertical adjustment red arrow Set up the terminal so that all 4 holes are over the blue arrows Make sure that there is a plastic disk at all fittings between AirLaser and the swivel head Use only the 6 x 18 screws together with a spring lock washer Now tighten the second screw for vertical alignment Attention For securing the screws use necessarily a sp...

Страница 9: ...ton B further functions e g Default Reset are possible see below 3 Reset Booting of the terminal The FSO link will be interrupted All system configurations are still valid Push button A B Push A an hold Now push B shortly to select the function you want The selected function is indicated by LEDs of the Local optical RX Level indicator When you are ready let A loose to execute the function Followin...

Страница 10: ...onfigure the IP address of the remote terminal before If the network connection to the remote terminal is interrupted even and odd numbered LEDs flashes alternating 12 Backup Antenna Not in operation 13 TP1 Port 10 100 1000BaseT Autonegotiation Port PD Maximum allowable cable length is 100m if this port is used only for power supply If data transmission is also used PoE special protocol the maximu...

Страница 11: ...ot be exceeded The terminal unit can optionally be screwed on a flat surface or it can be installed in 19 cabinets with an optional front panel The front panel has a height of 2U The electrical connection of the terminal unit depending on the version is made to one or two electrical outlets and a separate potential equalization The electrical connection must only be carried out by appropriately tr...

Страница 12: ...d when switching between optical and backup route is not done by the AirLaser IP1000plus but by the access switch Note When connecting the radio equipment to the terminal unit ensure that the TP cable of AirLaser IP1000plus and backups are not reversed AirLaser IP1000plus and the backup system use different PoE standard 12 Terminal unit version 2 with separate power supply for the AirLaser IP1000p...

Страница 13: ...y to the backup and data switching in the event of an interruption of the optical link If the AirLaser IP1000plus or the power supply fails through a technical defect the backup system can be plugged to the second port of the PoE injector unit In parallel the cable must be removed at TP1 and TP2 of AirLaser IP1000plus and connected by the enclosed coupling 13 Normal operation AirLaser and backup a...

Страница 14: ...ers allowed Select the button Search the Network In the new window you configure the search for AirLaser IP1000plus terminals There are two different search methods Multicast search and IP search Multicast search In case of multicast search your PC will send several multicast discovery packets with IP address 224 0 0 1 into the network All AirLaser IP1000plus which receive this packet will answer ...

Страница 15: ... of the AirLaser IP1000plus are listed Select the right terminal with help of the MAC address and push Set IP Configuration Now you can give AirLaser IP1000plus an IP address or you can activate the DHCP client 15 ...

Страница 16: ...Now the IP access to the terminal is configured and you can log into the webmanagement 16 ...

Страница 17: ...ults in the following changes to a firmware upgrade to version 2 03 The HTTPS protocol uses port 443 TCP Ensure that any firewalls are configured to access the AirLaser s 443 TCP port The certificate installed in the AirLaser IP1000plus is self signed by CBL and the same for all AirLaser IP1000plus Therefore when you first connect your Internet browser to the AirLaser you must confirm the certific...

Страница 18: ...e factory default setup identical with the user names admin and guest On the account side you may set up new passwords A password can have up to 64 characters If you don t set up a new password the former word is remaining 18 ...

Страница 19: ...r Number of transmitters IP1000plus 100 1 Single Beam IP1000plus 800 4 Quad Beam Hostname String 32 Serial number Name of the terminal in the network Domain String 32 unknown Domain of the AirLaser Location String 32 unknown Description of the installation place e g street number of the building Link Distance Integer Distance to the remote site 10 999 m The value is required for calculating the ex...

Страница 20: ...0 IP address of the primary DNS server DNS 2 IP 0 0 0 0 IP Address of the backup DNS server VLAN boolean disabled Enables disables VLAN support of the management VLAN ID Integer 1 Management VLAN ID Allow IP Config via Boolean HTML and Config Tool When set to HTML only the AirLaser configuration tool monitors the AirLaser only The network settings can therefore not be changed Remote Unit Identific...

Страница 21: ...group Following items can be configured for each port Mode of operation Type Description Default Path controlled port Preferred path to the data communication This path is used as soon as it is available Usually one uses the optical free space interface as default Path Backup Path controlled port The Backup Path is used whenever the default Path is interrupted As Backup System you can use the opti...

Страница 22: ...se you use the following settings Port Logic Application FSO Default Path free space path TP1 Local Port connection to your network and power supply TP2 Disabled not used With cable lengths of more as 90 meters between the AirLaser IP1000plus and the network connection we recommend the use of glass fibre as data line The following configuration is suitable for this case Port Logic Application FSO ...

Страница 23: ...SO Backup Path free space path TP1 Local Port connection to your network and power supply TP2 Disabled not used F1 Default Path dedicated line AirLaser IP1000plus with Webcam If you would like to supervise your fso link with an IP camera then you can attach this simply to the TP2 The port powers your camera if this is IEEE802 3af compatible Here our recommended settings Port Logic Application FSO ...

Страница 24: ...f the History The change between daylight saving time and normal time is made by the AirLaser IP1000plus automatically on the basis of the time zone if auto summer time is activated Type Default Description System Time Date not affected by a default reset current local time and date Time Zone Integer GMT 1 Berlin Rome Paris time zone of location of installation Auto Summer Time Boolean Enabled ena...

Страница 25: ...he interruption must rise so that the system changes over to the optical path Not until the value of optical hysteresis was exceeded the switch back time starts to run Type Default Description Optical Hysteresis Integer Disabled By this amount the optical level must exceed the sensitivity limit of the receiver so that the system changes over to the optical path Backup Delay Integer 500ms Time inte...

Страница 26: ...ransmit Power Control ATPC the transmission power is automatically increased to the maximum if the received power of the remote falls below 25dBm After reaching 12dBm receive power the preselected reduction is activated again TX Reduction Leistung in IP1000plus 100 IP1000plus 800 0dB 100 1 x 10mW 4 x 10mW 3dB 50 2 x 10mW 6dB 25 1 x 2 5mW 4 x 2 5mW 6dB with ATPC 25 100 1 x 2 5mW 1 x 10mW 4 x 2 5mW ...

Страница 27: ...minal Afterwards click on Activate to bring the new firmware from RAM into the FLASH You can see the progress in the log window It needs approximately 4 minutes After that the AirLaser IP1000plus boots automatically with the new firmware Your configuration still applies and if necessary it will be adjusted to the new config file Note AirLaser has only one storage for firmware During an update the ...

Страница 28: ...are for example the config file the log file current measured values and the history The system report is binary coded and encrypted The file can only be opened and read with a special software by the CBL customer service Thus it is the CBL customer service in case of a service request to quickly get an overview and to provide a comprehensive diagnosis Your login datas to AirLaser management that ...

Страница 29: ...For evaluation please send the file by email to the address lists of the CBL customer service staff 29 ...

Страница 30: ...30 seconds If you select Load Factory Settings the actual configuration will be deleted and a new with factory default set up will be valid see appendix B After booting the network configuration must be set up again Control TX power configuration for overload If an external backup system is connected to TP2 this port must be enabled and if necessary PoE support also 30 ...

Страница 31: ...0dB or 6dB During the test the link remains in the optical mode unless the receive power goes below the sensitivity limit of the receiver The AirLaser then automatically switches to the backup The measured value of each laser is associated with the laser in the image The view is to the rear of the unit From the Link Distance which is registered on the system site and the TX Reduction the Expected ...

Страница 32: ...n to the server which transmits data to the specified server address The test is thus unidirectional from client to server Due to the connection of the CPU of the AirLaser only data rates of about 80Mbit s can be generated After 10 seconds the test stops automatically For a full examination of the link test should now be started on the remote device Note Start the test on only one device so that t...

Страница 33: ...D you will find a graphics which shows the expected receive level for a given distance Note The usable range of the received signal level is from 32 5dBm to 2dBm In this range regardless of the level the entire bandwidth of 1000Mbit s full duplex is available For small levels so there is no reduction in data rate Below the level meter the monitor for the ports is shown Here you can see which port ...

Страница 34: ...own The port is not available for data transmission The cause can be seen from the bad messages System Temperature Temperature inside the unit in the area of the optical receiver Screen Temperature Temperature of the heated front screen APD Factor The APD Factor is a measure for the gain of the optical receiver Input Power Status of both PoE input controller 3 3V Voltage Internal 3 3 volt operatin...

Страница 35: ...At the bottom of the site you find the System Time i e the current local time of the system and the Uptime i e the time that has elapsed since the last boot 35 ...

Страница 36: ...ers for the logfile in order to find certain events more easily If you set one or more checkmarks in the port filter only the events that affect these ports are displayed With the event filter you can search the message text for specific terms This is case sensitive You can also enter several search terms separated by comma Spaces are not allowed here The Severity filter is used to turn events of ...

Страница 37: ...7 13 Port counter Portcounter counts received and transmitted bytes and frames at each port of the AirLaser With this counter specially the error counter possible problems can be seen 37 ...

Страница 38: ... and traffic counters up to one month These are optical RX power system temperature power in the APD fso and tp2 monitoring frames fso f1 tp1 and tp2 rx and tx bits fso f1 tp1 and tp2 rx bitserrors The curves can help to have a look on the quality of the link 38 ...

Страница 39: ...p devices are entered on the Port Control Site Typ Default Beschreibung Link Monitoring Boolean disabled Enables disables backup link monitoring with auto reboot function Link Monitoring Timeout Integer 300 Timeout of the link monitoring packets until a reboot of the backup takes place Typ Default Beschreibung SNMP Monitoring Boolean disabled Enables disables SNMP monitoring of the built in backup...

Страница 40: ...40 ...

Страница 41: ... String 64 IP Address or domain name of the SMTP Servers SMTP Port Integer 25 Portnumber of the SMTP Server User String 64 Username of AirLaser on the SMTP server Password String 64 AirLaser password for the SMTP access Type Default Description Enable Checkbox Enable disable sending emails to a specified address Address String 64 Email address of recipient Monitored Event Classes Checkbox Determin...

Страница 42: ...remote syslog server Because the syslog protocol is not secured it is possible that log entries are lost Type Default Description Remote Syslog boolean disabled Enable or disable sendig messages to a remote syslog server Host Address String 64 IP address or domain name of the syslog server Portnummer Integer 514 Portnumber of the syslog server 42 ...

Страница 43: ...queues Queue 3 has the highes priority queue 0 the lowest Assignment of 802 1q priority values to the four output queues of the switch 802 1q priority value 0x0 0x1 0x2 0x3 0x4 0x5 0x6 0x7 Output queue of the switch port 0 0 1 1 2 2 3 3 Assignment of 64 DiffServ or Traffic Class values to the four output queues of the switch DiffServ value 0x00 to 0x0F 0 to 15 0x10 to 0x1F 16 to 31 0x20 to 0x2F 32...

Страница 44: ...ce F1 optional Fiber optic Multimode opt Singlemode Wavelength 850 1310 nm Connector SC RJ IP67 waterproof Standard 1000BaseSX opt 1000BaseLX TX power 4 10 dBm RX sensitivity 16 0 850nm 20 3 1310nm dBm TP1 PD PoE Standard proprietary Connector RJ45 IP67 waterproof Standard 10 100 1000BaseTX Autonegotiation Auto Crossover TP2 PSE PoE Standard IEEE802 3af or forced mode Power 20W 48VDC W Connector R...

Страница 45: ...55 VDC DC output current 2 x 700 mA Temperature range 0 55 C Dimensions without frontpanel 42x21x4 4 Width x Depth x Hight cm Weight 1 5 kg PoE option for backup AC input voltage 100 250 50 60Hz VAC Power factor corresponding to EN61000 3 2 DC output voltage 48 VDC DC output current 670 mA Temperature range 0 40 C Weight 0 25 kg Last changed November 2013 45 ...

Страница 46: ...ID 1 Allow IP Config via HTML and Config Tool Remote IP Address 0 0 0 0 Field Value Port Logic FSO Default Path TP1 Local Port 1000Mbit s Autonegotiation TP2 disabled F1 optional Local Port 1000Mbit s Autonegotiation External Backup Tunnel Static MACs at TP1 none Static MACs at TP2 none Static MACs at F1 none Field Value Time Zone GMT 1 Berlin Rome Paris Auto Summer Time enabled NTP Service disabl...

Страница 47: ...one Recipients none Appendix C Alarm thresholds Value Critical Min Warning Min Warning Max Critical Max 3 3 Volt 3 135V 5 3 204V 3 3 399V 3 3 465V 5 2 5 Volt 2 375V 5 2 425V 3 2 575V 3 2 625V 5 APD temperature 15 C 10 C 70 C 75 C Heater temperature 1 C 3 C 50 C 55 C Heater current off 0mA 0mA 20mA 20mA Heater current on till HW 1 2 650mA 750mA 1200mA 1250mA Heater current on from HW 1 3 800mA 900m...

Страница 48: ...Appendix D Expected Receiving Level 48 ...

Страница 49: ...49 ...

Страница 50: ...5dBm 4dBm 2 5dBm 50 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 6 7 5 8 4 3 2 1 ...