MAIN PARTS OF THE ELECTRICAL SYSTEM
> LEISURE BATTERY “B2” - it gives power to all the users.
>
“PC380-BS”
CONTROL PANEL
- mains’ control, battery test, tank test, temperature test and clock unction
f
> 12V DISTRIBUTION BOX “DS
”
520-AN - main relais, battery parallel relais (12V - 70A), fridge relais,
pump relais, car battery recharging device, protection fuses.
>
BATTERY “B1”
CAR
.
> ELECTRONIC TANK PROBE - it measures the content of the water tanks, visualization in “%”
.
ADVICE AND CHECKS
If the leisure battery is removed, isolate the positive
pole (in order to avoid short-circuits during an
accidental car engine starting).
The battery charger must be installed in a dry and
ventilated place.
The installation of this device must be carried out by
specialized technicians.
In case of battery charger’s misuse, the guarantee
falls off and the manufacturer declines all responsi
bility for damages to people and things.
-
Do not carry out any maintenance when the battery
BATTERIES
Check the correct tightening of the connection binding
screw and brush off the oxyde.
Check periodically the level of the liquid of the battery
(with acid); the GEL battery does not need any main
tenance but a countinuous recharging.
-
In case of a longer stop, the services battery has to be
disconnected or recharged regularly.
BATTERY CHARGER
R
-
ead with care the instructions of use and main
tenance of the batteries.
The acid kept in the batteries is poisoning and
corrosive. Avoid any contact with skin and eyes.
If the battery is completely discharged it needs
recharging for almost 10 hours. If discharged for more
than 8 weeks it may be damaged.
When the fuses are replaced respect the value of the
amperage established.
In order to cut power to the whole 230V system,
please take care that the 230V main switch must be
on the “0” (OFF) position.
Replace the fuses after finding out the real cause of
the damage only.
Before taking away the cover, check that the 230V
socket is disconnected.
Before disconnecting the battery charger from 230V
power supply, turn the security switch off.
230V CUT-OUT BOX
Connect and disconnect the external 230V net only
when the main switch is off.
In order to avoid damages to the box, check the
correct tightening of the connections.
TANK PROBES
In case of automatic switch break, find the damage
before giving power again to the electrical system.
Do not cover air intakes and assure an appropriate
ventilation.
FUSES
Never let water in the tanks for long time, in order to
avoid foulings, especially in the waste water tank.
charger is connected to the 230V power supply net.
IMPORTANT Maintenance interventions on the electric implant must be carried out by
specialized personnel. Before carrying out maintenances disconnect the battery and the
230V alimentation line.
: