14
PUTTING INTO OPERATION
ASSEMBLY
1. Remove the handle and jack from the packaging.
2. Undo the nut no. 3083 and remove screw no. 3081 from the chassis together with its washer
no. 0805. When removing the screw take care not to lose the pin inside no. 3076.
3. Insert the handle with the air distributor facing the worker.
4. insert the parts removed previously into the hole of the handle, insert the screw no. 3081 and
then tighten with nut no. 3083.
5. Connect the air pipe that comes out of the handle to the quick coupling on the base.
CONNECTION TO THE COMPRESSED AIR SYSTEM
- Compressed air enters into the jack circuit through the quick coupling on the top of the manual
lifting/descending controls; it is therefore necessary to have a connecting pipe with a quick
coupling compatible with that of the jack. Check that the air supply pipe has a useful passage of at
least 6 mm and it is not pinched or restricted anywhere.
DWG. 7
WORKING AIR PRESSURE: 7 - 10 BAR
- Absolutely never put the following into the compressed air circuit: hydraulic or Vaseline oil, brake
liquid, kerosene or other liquids.
-Install a filter dehumidifier-lubricator unit in the compressed air system.
- If you want to lubricate the compressed air circuit use exclusively:
AGIP OSO 100; MOBIL DTE 27; ESSO TERESSO 100;
SHELL TELLUS 100; BP ENERGOL HP 100
ACCESSORIES
The jack is supplied with two extensions or height adapters (120 mm the long extension, 70 mm
the short extension), a circular tooth plate (10 mm plate) and an extension holder.
THE MANUFACTURER IS NOT LIABLE FOR ANY DAMAGE
RESULTING AS A CONSEQUENCE OF DISREGARD FOR THE ABOVE
INDICATIONS AND THE WARRANTY CONDITIONS ARE INVALIDATED
THEREOF!
SCRAPPING AND DISPOSAL
- Scrapping the jack and its component parts must be carried out by the user in accordance with
current laws.