Stronger, with Castolin Eutectic
29
www.castolin.com www.eutectic.com
diameter used, open the mobile lateral side, remove the
cover CA, release the wire press rollers by means of the pres-
sure adjusting knob BN, replace the rollers and remount the
cover CA. (See fig. 5).
Mount the wire coil and slip the wire into the feeder and
welding torch sheath.
Block the wire press rollers with the knob BN and adjust the
pressure.
Turn on the machine.
Adjust the gas by means of key AY and then feed the wire by
means of key AW.
7 WELDING
Welding Synergic Pulsed MiG LED AP on.
Select the PRG number based on the wire diameter to be
used, the type and quality of the material, and the type of
gas, using the instructions located inside the wire feeder
compartment.
Set the functions in the submenu according to the instruc-
tions under paragraph «Service functions».
5.2.3The welding parameters are set by means of knobAI.
Synergic MiG Welding LED AQ on.
Select the PROG number based on the wire diameter to be
used, the type and quality of the material, and the type of
gas, using the instructions located inside the wire feeder
compartment.
Set the functions in the submenu according to the instruc-
tions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI.
Conventional MiG Welding LED AR on.
Select the PROG number based on the wire diameter to be
used, the type and quality of the material, and the type of
gas, using the instructions located inside the wire feeder
compartment.
Set the functions in the submenu according to the instruc-
tions under paragraph «Service functions».
Adjust the wire speed and the welding voltage using the
knob AI. and AN respectively.
MMA Welding LED AT on.
Connect the earth terminals and the cable terminals of the
electrode clamp to terminals DandA observing the polarity
stated by the electrode manufacturer. Set the functions in
CA
BN
BN
Fig. 5
the submenu according to the instructions under paragraph
«Service functions».
Adjust the welding current using the knob. AI.
8 MAINTENANCE
Any maintenance operation must be carried out by qualified
personnel in compliance with standard CEI 26-29 (IEC 60974-4).
8.1 GENERATOR MAINTENANCE
In the case of maintenance inside the machine, make sure
that the switch L is in position "O" and that the power cord
is disconnected from the mains.
Even though the machine is equipped with an automatic
condensation drainage device that is tripped each time the
air supply is closed, it is good practice to periodically make
sure that there is no condensation accumulated in the water
trap J (fig.1).
It is also necessary to periodically clean the interior of the
machine from the accumulated metal dust, using compres-
sed air.
8.2 PRECAUTIONS AFTER REPAIRS.
After making repairs, take care to organize the wiring so that
there is secure insulation between the primary and secondary
sides of the machine. Do not allow the wires to come into con-
tact with moving parts or those that heat up during operation.
Reassemble all clamps as they were on the original machine, to
prevent a connection from occurring between the primary and
secondary circuits should a wire accidentally break or be di-
sconnected.
Also mount the screws with geared washers as on the origi-
nal machine.
Содержание MIG PULSE 3003 DP
Страница 48: ...www castolin com www eutectic com Stronger with Castolin Eutectic 48...
Страница 50: ...www castolin com www eutectic com Stronger with Castolin Eutectic 50...
Страница 52: ...www castolin com www eutectic com Stronger with Castolin Eutectic 52...
Страница 54: ...www castolin com www eutectic com Stronger with Castolin Eutectic 54...