53
Every start-up
Every 2 months
Every 6 months
Disposal
Care, maintenance and disposal
General remarks
Warning!
An electric shock can be fatal. Before opening up the machine
-Shift the mains switch into the "OFF" position
-Unplug the machine from the mains
-
Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
-Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have been discharged
-Check mains plug, mains cable, welding torch, interconnection cable assembly and
bondings for damage
-Check whether the allround distance of 0.5 m (1.6 ft.) is kept to ensure that the
cooling air can easily flow and escape.
Note!
Furthermore, air inlets and outlets must in no case be covered, not even
covered partly.
-Optional: clean air filter
-Dismantle machine side panels and clean machine inside with dry reduced com-
pressed air
Note!
Risk of damage to electronic components. Clean electronic components
from a certain distance only.
-If a lot of dust has accumulated, clean the cooling-
air ducts.
Carry out disposal in accordance with the valid national and local regulations.
Under normal operating conditions the power source requires only a minimum of care
and maintenance. However, it is indispensable to follow some important points to ensure
the operationality of the welding machine for many years.