24
For information on setting the “Spot-welding time” set-up parameter (SPt), see the
section headed “The Set-up menu: Level 1”.
If a value has been set for the “SPt” set-up parameter, the operating mode “2-step
mode” (2) will have the function of the spot-welding mode.
Spot-welding status indicator: Remains lit up as long as a value has been speci-
fied for the spot-welding time.
-Select 2-
step mode (2)
-
In the “Set-up menu: Level 1”, set the “SPt” set-up parameter to the desired spot-
welding time.
-Welding: Briefly push forward the torch trigger
To abort this procedure, push forward the torch trigger once again.
Important! When using a remote-control pedal unit: The spot-welding time starts to
elapse as soon as you actuate the remote-control pedal unit. It is not possible to regulate
the power using the remote-control pedal unit.
I
Fig.7
Spot welding
t
I
1
GPr
t
1
t
2
SPt
G-L
G-H
Spot welding
Содержание CastoTIG
Страница 2: ......
Страница 4: ......
Страница 16: ...ud_ca_st_sv_00676 032003 XII ...
Страница 76: ...CastoTIG 2201 DC ...
Страница 77: ...CastoTIG 1702 AC DC ...
Страница 78: ...CastoTIG 2202 AC DC ...