Cast Tec Arbeia Juno Скачать руководство пользователя страница 14

 

13

 

Juno & Vulcan 

Issue 01 06/13

 

 
DO NOT perform modifications to the appliance as this could seriously 
compromise safety in operation. 
 
DO NOT OVERFIRE

 

– it is possible to fire the stove beyond its design capacity, this 

could damage the stove, so watch for signs of over firing 

– if any part of the stove starts 

to glow red, including baffle plate or fuel retainer, the fire is in an over fire situation and 
the controls should be adjusted accordingly. Never leave the stove unattended for long 
periods without first adjusting the controls to a reduced and safe setting 

– 

careful air 

supply control should be exercised at all times

 

WARNING 

– FUME EMISSION 

Properly installed and operated, this appliance will not emit fumes. Occasional fumes 
from de-ashing and refuelling may occur which is not normally of serious concern. 

However,

 

persistent fume emission is potentially dangerous and must not be 

tolerated.

 

If fume emission does persist, then the following immediate action should be taken: - 
 

1. 

Open doors and windows to ventilate room 

2. 

Let the fire out, or remove and safely dispose of fuel from the appliance. 

3. 

Check for flue chimney blockage and clean if required. 

4. 

Do not attempt to re-light the fire until the cause has been identified and 
corrected. 

If necessary, seek professional advice from chimney or stove specialists. 
 

Important! 

– 

Do not fit an extractor fan in the same room as this appliance. 

 
IN THE EVENT OF A CHIMNEY FIRE 

 

Raise the alarm to let others in the house know. 

 

Call the Fire Service 

 

Reduce the appliance burning rate by closing all air controls fully. 

 

Move furniture and rugs away from the fireplace and remove any nearby 
ornaments. 

 

Place a fireguard or spark guard in front of the stove. 

 

Feel the chimneybreast for sign of excessive heat. 

 

Do not relight the fire until the chimney and flue ways have been examined by 
a professional. 

 
If the wall is becoming hot, move the furniture away. Ensure that the Fire Service can 
gain access to your roof space in order to check this area for signs of fire spread. 
 

CO ALARMS 

Your installer should have fitted a CO alarm in the same room as the appliance. If the 
alarm sounds unexpectedly, follow the instructions given under 

“Warning Note” below. 

WARNING If the CO Alarm sounds unexpectedly:- 
1. Open Doors and windows to ventilate the room and then leave the premises. 
2. Let the fire go out

Содержание Arbeia Juno

Страница 1: ...times Instructions for wood burning MUST be followed in order to ensure compliance at all times Arbeia Juno Arbeia Vulcan FREESTANDING STOVE RANGE 5 8 kW Nominal Outputs Installation and Operating Ins...

Страница 2: ...ortant safety information 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 6 4 6 Hearths 6 4 7 Commissioning Handov...

Страница 3: ...MAY BE PACKED ON TOP OF THE BAFFLE PLATE REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT See List of Components section and check contents carefully 2 1 To remove the baffle plate first remove the tw...

Страница 4: ...documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful In addition to these instructions the requirements of BS 8303 and BS EN 15287 must...

Страница 5: ...skin In case of skin contact wash immediately with plenty of water 3 1 10 Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation th...

Страница 6: ...the rate of burning can be controlled to prevent over firing 4 4 Connection to the Chimney This appliance is not suitable for use in a shared flue When using a liner a 5 flexible flue liner is permitt...

Страница 7: ...m must be left around the sides and top and at least 50mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance A clearance of 150mm will gi...

Страница 8: ...re correctly fitted and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use...

Страница 9: ...d from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt applia...

Страница 10: ...ted part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that assist...

Страница 11: ...ll then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes or...

Страница 12: ...indling sticks and or firelighters If using Ancit place a layer of ancit into the firebox as well Light the fire at the base leaving the secondary air control fully open Leave the door slightly ajar f...

Страница 13: ...open first and then open the secondary air controls Warning The stove will remain very hot for a considerable time after the fire has died down or been extinguished Notes Warning Petroleum coke fuels...

Страница 14: ...pose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek profes...

Страница 15: ...14 Juno Vulcan Issue 01 06 13 8 1 Arbeia Juno Stove Dimensions 8 2 Arbeia Vulcan Stove Dimensions...

Страница 16: ...d to product failure 6 Where can I get spare parts Your local Cast Tec stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Cast...