Cast Tec Arbeia Juno Скачать руководство пользователя страница 13

 

12

 

Juno & Vulcan 

Issue 01 06/13

 

NOTE: To eliminate unwanted smoke emission, after loading new logs on to the fire, 
open the air wash control up fully for 3-5 minutes or until the logs are blackened all over 
to boost the fire and get flames issuing from the top of the fuel as soon as possible. 
When flames are well established, reduce the air wash to the running setting required. 

Burning without flames above the fuel will create unnecessary smoke

. Do not load 

fuel above the tertiary air inlet holes at the back of the firebox. 
 
Loading 3 to 4 medium sized logs will produce a good output with reasonable burn time, 
generally small logs will burn up quicker producing a high output for a short time and a 
large log will take longer to burn and produce less output over a given time. These 
appliances are approved for intermittent operation on wood (0.75 to 1.5 hour burn 
cycles) although much longer burn times can be achieved by fully loading the firebox, 
getting the fuel burning well and then shutting the air controls right down (see below). 
The fire will then need reviving by first opening the air controls and then using small 
pieces of wood and plenty of air to get flames issuing from the wood again. 
 

6.9 Shutting Down 

The stove will normally shut down by itself as the fuel is consumed. In order to shut 
down the stove for other reasons, close the primary air controls (if open), then close the 
secondary air control. If the controls are left in this position, the fire will eventually go 
out. If you want to revive the fire it is recommended that the primary air controls are 
open first, and then open the secondary air controls. 
 

Warning! - 

The stove will remain 

very hot 

for a considerable time after the fire has died 

down or been extinguished. 
 

Notes: Warning!- Petroleum coke fuels or household waste must not be burnt on 
this appliance.  

Should any difficulties arise over fuel quality or suitability, consult your local approved 
fuel merchant. 

 
6.10 Shut down for prolonged periods 

If the stove is to be left unused for a prolonged period of time then it should be given a 
thorough clean to remove ash and unburned fuel residues. To enable a good flow of air 
through the appliance to reduce condensation and subsequent damage, leave the air 
controls fully open. It is important that the flue connection, any appliance baffles or 
throat plates and the chimney are swept prior to lighting up after a prolonged shutdown 
period. 
 

6.11 Maintenance 

Inspect the inside of the firebox and above the baffle plate every week during use. 
Where the chimney is believed to have previously served an open fire installation, it is 
possible that the higher flue gas temperature from the stove may loosen deposits that 
were previously firmly adhered, with the consequent risk of flue blockage. It is therefore 
recommended that the chimney be swept a second time within a month of regular use 
after installation. 

See chimney cleaning section in section 3.1 Warnings and 

Important Information.

 Inspect the inside of the stove and the flue ways and ensure 

they are 100% clear after a period of disuse (e.g summer). 

Only use manufacturers 

recommended replacement parts on the appliance. 

 

7.0  Safety Notes for your guidance 

FIRES CAN BE DANGEROUS

 

– Always use a fireguard to BS 8423:2002 Fireguards 

for use with solid fuel appliances in the presence of children, the elderly or the infirm.  

Содержание Arbeia Juno

Страница 1: ...times Instructions for wood burning MUST be followed in order to ensure compliance at all times Arbeia Juno Arbeia Vulcan FREESTANDING STOVE RANGE 5 8 kW Nominal Outputs Installation and Operating Ins...

Страница 2: ...ortant safety information 3 4 Installation Information 4 4 1 Chimney 4 4 2 Ventilation 5 4 3 Flue Draught 5 4 4 Connection to Chimney 5 4 5 Material Clearances 6 4 6 Hearths 6 4 7 Commissioning Handov...

Страница 3: ...MAY BE PACKED ON TOP OF THE BAFFLE PLATE REACH THROUGH THE TOP SPIGOT OPENING TO FIND IT See List of Components section and check contents carefully 2 1 To remove the baffle plate first remove the tw...

Страница 4: ...documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful In addition to these instructions the requirements of BS 8303 and BS EN 15287 must...

Страница 5: ...skin In case of skin contact wash immediately with plenty of water 3 1 10 Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation th...

Страница 6: ...the rate of burning can be controlled to prevent over firing 4 4 Connection to the Chimney This appliance is not suitable for use in a shared flue When using a liner a 5 flexible flue liner is permitt...

Страница 7: ...m must be left around the sides and top and at least 50mm at the back of the stove to obtain reasonable heat output and for access to the stove for removal and maintenance A clearance of 150mm will gi...

Страница 8: ...re correctly fitted and ensure that the operating instructions and operating tools including gloves for the stove are left with the customer You must be sure to advise the customer on the correct use...

Страница 9: ...d from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs has powers under the Act to authorise smokeless fuels or exempt applia...

Страница 10: ...ted part of the multi tool into the knob and lifting up and down or pulling and pushing the knob depending on the model The grate is a strong set of cast iron bars with suitable air slots that assist...

Страница 11: ...ll then control the burn rate of the stove Always make sure that flames are visible above the wood after re fuelling for cleanest burning After re fuelling open the air wash full for 3 to 5 minutes or...

Страница 12: ...indling sticks and or firelighters If using Ancit place a layer of ancit into the firebox as well Light the fire at the base leaving the secondary air control fully open Leave the door slightly ajar f...

Страница 13: ...open first and then open the secondary air controls Warning The stove will remain very hot for a considerable time after the fire has died down or been extinguished Notes Warning Petroleum coke fuels...

Страница 14: ...pose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek profes...

Страница 15: ...14 Juno Vulcan Issue 01 06 13 8 1 Arbeia Juno Stove Dimensions 8 2 Arbeia Vulcan Stove Dimensions...

Страница 16: ...d to product failure 6 Where can I get spare parts Your local Cast Tec stove retailer will be pleased to supply spare parts and to provide any other information you require Alternatively contact Cast...

Отзывы: