14
15
Operation
Operation of FAMILY 30
The control and its button are located in the cabin.
The tank unit is fitted to the back of the tractor (or other suitable
vehicle).
The operator must select the suitable timer on the Control in order
to achieve the desired quantity of liquid to be dispensed for each
single spot.
When the button is pressed, the liquid within the tank
is drafted by means of the 12V electric pump.
Dispensing is opened by one solenoid valve, also 12V.
While the spot is dispensed, the solenoid valve controlling the agitator
automatically closes to ensure the proper pressure for the jets.
Operation of control in cabin
1) Turn on
FAMILY 30
by means of the main switch
ON/OFF
.
2) Select one side by means of the lever switch.
Set the timer to approx. 2 seconds and press the button several times
until liquid comes out.
3) Repeat the same operation on the opposite side.
4) Use a measuring cup (supplied) to adjust the timer until the product
dose to be dispensed is achieved for each single spot. We recommend
performing the first calibration by using water only.
The tractor must be on to ensure that the current supplying the entire
machine is constant, ensuring greater adjustment accuracy.
Ensure that nobody can access the tractor and inadvertently engage
the forward movement. The tractor must be in neutral and the brakes
must be engaged to prevent the tractor from moving.
The control includes a switch (circuit washing) that bypasses the timer
and is used to wash the entire circuit (see page 23)
Technical information
B