16
Distribution
- Principle of calibrated overlap
The continuous overlap of dispensed liquid is the principle behind our
systems, a characteristic that ensures that distribution is uniform also on
particularly harsh grounds.
The unit of measure used to determine the uniformity of distribution is the
CV (Coefficient of Variation), whose value is a percentage.
According to current regulations, CV must be within 0% (absolute uniformity)
and 10%.
Position DUPIGET PRECISION at 50/60 cm from the ground or the vegetation.
The actual operating width, including the side fading, is always approx. 13
m, but the principle of calibrated overlap allows continuing through lanes
with different distances without any issues due to a lack of uniformity of
distribution or excessive dosing.
With 9 m passes, a CV of 8.1% is achieved, with 8 m CV is 3.5% and with
passes every 5 m CV falls event to 1.8%, almost reaching perfection.
DUPIGET PRECISION can be used to operate on a single side, simply by
closing one of the two deliveries.
Use DUPIGET PRECISION with a pressure of 10 bar.
4.5 m minimum
9 m maximum
overlap
on the sides
13 / 14 m *
13 / 14 m *
* Values are an indication only, external factors may change them slightly