5-3. Low voltage monitoring
There are four low voltage detection levels on the hardware of the device.
Level
Content
Operation
Action on next start-up
VDET1
Warning on voltage reduction of
main battery
Display of warning on
voltage reduction of main
battery
―――――
VDET2
Power OFF due to voltage
reduction of main battery
Power OFF
Resume (with warning
message on start-up)
VDET3
Emergency power OFF due to
voltage reduction of main battery
Critical power OFF
Warm boot (with warning
message on start-up)
VDETPC
Power OFF due to PC voltage
reduction
Power OFF
Resume (with warning
message on start-up)
Voltage monitoring of the main battery
English indication
Details
Status External
External power source
The power is supplied from an external power source
and charging is completed.
Charge
Battery is under charging The power is supplied from an external power source
and charging is in progress.
Normal
Main battery
The device is battery operated.
Level
1
O.K.
The battery is fully charged or the remaining power of
the battery is sufficient for operation of the device.
2
Low
The remaining power of the battery is half or less.
3
Very low
When VDET1 is detected.
<The status and the level of the main battery>
The battery status is usually checked at a 5-second interval.
Only during the property of Power Management is displayed, the battery status is checked at a 1-second
interval.
Calculate the average of the previous 10 data on the AD converter for the power supply voltage, categorize
the values into "Very low (10%)", "Low (25%)", and "O.K. (75%, 100%)" and display in text. Occurrence of
VDET1 means 10%.
Содержание IT-3100
Страница 1: ...SERVICE MANUAL HANDHELD TERMINAL IT 3100 Series PX 780 JUL 2008 Ver 4 Feb 2011...
Страница 14: ...12 3 4 COMPONENTS LOCATION ON THE MAIN PCB...
Страница 15: ...13...
Страница 90: ...88 UPPER CASE PW FPC KEY FPC 1 2 3 5 6 1 4 6 2 6 1 1 2 1 3 1 1 4 7 9 8 8 8 111 113 114 112 9 2 9 1...
Страница 93: ...91 ROLL PAPER HOLDER 48 8 48 8 48 2 48 4 48 5 48 1 48 3 48 6 48 7 48 9 48...