QW-5117
TEST MODE
7-7-77
From the Timekeeping mode, hold down
�1
D
and press
B
and
C
at the same time to start the
Time Calibration Signal Test mode. The last receiving station will be indicated.
Each time
21
D
is pressed, the test signal receiving station changes as shown below:
JJY40 (J40) → JJY60 (J60) → WWVB (U60) → DCF77 (G77) → MSF (L60) → BPC1 (B01) →
BPC2 (D02) → BPC3 (G03) → BPC4 (T04)
Press
3
1
B
while in a receiving station state to start receiving a signal.
* Be sure that the Mode hand is at the R position.
Press any button while receiving a signal to return to the Timekeeping mode.
41
In approximately 15 minutes, check the indication and determine the result by referring to the table
5
1
below.
While in the Time Calibration Signal Test mode, you may press
�1
C
to exit the Time Calibration
Signal Test Mode and return to the Timekeeping mode.
J40
J60
U60
G77
L60
D02
40 kHz (JJY40)
60 kHz (JJY60)
60 kHz (WWVB)
77.5 kHz (DCF)
60 kHz (MSF)
the factory test in China (BPC)
BPC2
D02
BPC1
B01
BPC3
G03
BPC4
T04
JJY40
J40
JJY60
J60
WWVB
U60
DCF77
G77
MSF
L60
LCD
TYO
NYC
PAR,LON
HKG
D
+
C
+
B
JJY40
JJY60
WWVB
DCF77
MSF
BPC1
BPC2
BPC3
BPC4
OK
J40 OK
J60 OK
U60 OK
G77 OK
L60 OK
B01 OK
D02 OK
G03 OK
T04 OK
NG
J40 NG
J60 NG
U60 NG
G77 NG
L60 NG
B01 NG
D02 NG
G03 NG
T04 NG
Indication of the Last Receiving Station
C
or A.R
Selecting the Time Calibration Signal Receiving Station
To check in China, us BPC2.
D
D
D
D
B
D
D
D
D
D
D
Time keeping mode
Last Receiving Sttn
Home city
Receiving start:
Ready
Work
Reception OK
Reception NG
Reception result (Example;JJY40)
While signal reception
Reception Result
signal
reception