QW-5117
INSTALLING HANDS
6-66
Procedures
Button operations, additional instructions
1. Press fit the Mode hand
1) Enter the Mode hand adjustment mode
AC →
A
→ Wait for 3 sec
2) Adjust the polarity of the Mode hand
B
× 2 times
3) Align the Mode hand at the 12:00 position and
press fit the hand
2. Press fit the STW hand
1) Enter the STW hand adjustment mode
AC →
A
→ Wait for 3 sec
2) Adjust the polarity of the STW hand
D
× 2 times
3) Align the STW hand at the 12:00 position (60)
and press fit the hand
3. Press-fitting the hour and minute-hands
1) Enter the Hour/Minute hands adjustment mode
C
2) Press fit the Hour hand
Slightly before 12:00
3) Align the Hour hand at the 12:00 position
Align the position by
D
(normal rotation)
4) Enter the Hour/Minute hands adjustment mode AC →
A
→ Wait for 3 sec →
C
5) Press fit the Minute hand at 0-min. position
4. Checking the polarity of the Mode / STW hands
1) Enter the Mode/WT hands Adjustment mode
AC →
A
→ Wait for 3 sec
2) Confirm that each of the Mode and the
STW hands moves one step at a time when
pressing a respective button
(Within ±1.5° : Figure 1)
D
→
B
6. Checking the accuracy of the Hour hand
1) Enter the Hour/Minute hands adjustment mode AC →
A
→ Wait for 3 sec →
C
2) Confirm the hour hand position when the
minute hand indicates 11:57
Align the position with
D
(normal rotation)
→ The hour hand:12 o’clock or slightly late
3) Confirm the hour hand position when the
minute hand indicates 00:03
Align the position with
D
(normal rotation)
→ The hour hand:12 o’clock or slightly fast
Location of the buttons and name of the hands
STW hand
Hour hand
Minute hand
Mode hand
12H
6H
Shorter end
Longer end
STW hand
Mode hand
Make sure that the markin
on the DIAL is covered by
the hand completely
.
±1.5°
Figure 1
±1.5°
Shorter end