![Casio DT-X400 Series Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/casio/dt-x400-series/dt-x400-series_user-manual_2568861050.webp)
E-48
Precautions for Use
• Even if the battery in the DT-X400 is already fully charged, charging will begin when
you set the DT-X400 in the Ethernet cradle. It may take several minutes for the fully
charged status to be indicated.
• In high- or low-temperature environments, charging may be restricted to protect the
battery pack. At such temperatures, the level of battery charge may not reach 100%
even when the charging status LED is green and charging is completed.
• Water or other moisture on the power contacts could cause sparking or an electric
shock, and soiled contacts could block the connection and impair charging
functionality. To ensure safety, clean the power contacts by wiping them off with a
dry cloth or cotton bud after you disconnect the AC adapter.
• When disconnecting the AC adapter from the mains power outlet and DT-X400, do
so by gripping the connector and not by pulling on the cord.
Ethernet Cradle (HA-S62IO) Specifications
1. LAN specifi cations
Communications method : IEEE 802.3-compliant
Media type
: 10base-T/100base-TX auto switched
2. Charging specifi cations
Charging method
: Constant-voltage constant-current charging
Charging time
: Approx. 4 hours
3. AC adapter specifi cations
Standard
: AD-S50400A
Input
: 100-240V AC, 50/60 Hz, 0.7A
Output
: 5V DC, 4A
4. Dimensions, weight
Dimensions
: Approx. 102(W) × 140(D) × 131(H) mm
Weight
: Approx. 380g
5. Operating environment
Operating temperature
: 0°C to 40°C
Operating humidity
: 10-90% RH (condensation-free)