Operation Guide DQR-300
4
Battery precautions
•
Keep batteries out of the reach of small children. If a battery is accidentally swallowed, contact your physician
immediately.
•
Be sure to load the batteries with their positive (+) and negative (–) ends facing correctly.
•
Never mix old and new batteries, or batteries of different brands.
•
Never charge the batteries that come with the clock.
•
Should batteries ever leak while in the clock, wipe out the fluid with a cloth, taking care not to let any get onto
your skin.
•
Replace the batteries at least once a year, even if the current batteries are working properly.
•
The batteries that come with the clock lose some of their power during transport and storage.
THERMOMETER FUNCTIONS
Both the main unit and the sub-unit are equipped with their own temperature sensors. Temperature data measured
by the sub-unit is sent by wireless transfer to the main unit. You can toggle the main unit display between the main
unit temperature reading and the sub-unit temperature reading. This makes it possible to view both the indoor and
outdoor temperature on the main unit display.
Temperature Measurements
•
Both the main unit and the sub-unit take temperature measurements every 16 seconds.
•
The temperature display shows “LO” for temperatures below –50
°
C (–58
°
F) and “HI” for temperatures above
70
°
C (158
°
F).
•
Though temperature readings are displayed up to 0
°
C (32
°
F) and greater than 41
°
C (105
°
F), note that such
readings are actually outside the guaranteed temperature range of this clock.
Switching between Celsius and Fahrenheit
•
Push the
°
C/
°
F button (
0
) to select either Celsius (
°
C) or Fahrenheit (
°
F).
Celsius (
°
C)
Fahrenheit (
°
F)
°
C/
°
F button
(
0
)
°
C
°
F
Switching between Main Unit and Sub-unit Temperature Data
•
Press the SELECT button (
B
) to toggle the display between the main unit (INDOOR) temperature and the sub-
unit (OUTDOOR) temperature.
Main unit temperature: INDOOR indicator displayed
Sub-unit temperature: OUTDOOR indicator displayed
•
The display does not change to the sub-unit (OUTDOOR) temperature if no data has been received from the sub-
unit yet.
•
Holding down SELECT button (
B
) for about two seconds causes the display to continually toggle between the
main unit and sub-unit temperature at five-second intervals.
Main unit
Sub-unit
SELECT button
(
B
)
INDOOR
OUTDOOR
High Temperature and Low Temperature Memory
•
The following data is stored in memory automatically.
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature
•
To clear the high temperature and low temperature data memory, press the CLEAR button (
9
).
New data starts to be stored after memory is cleared.
CLEAR button (
9
)
MAX/MIN TEMP. button (
7
)
Main unit high temperature and low temperature
Sub-unit high temperature and low temperature
Current temperature and humidity