background image

Conforms to

  

UL Std. 217

 

8th Edition

Helps Reduce Cooking Nuisance Alarms

®

MODEL AMI1061S 

Multi-Criteria Single/Multiple Station Smoke Alarm

Universal Sensing Plus

® 

2-in-1 Smoke & Fire Alarm  

with 10 Year Tamper Proof,  

Permanent Power, Lithium-Free, 

Sealed Battery Backup

THANK YOU for purchasing this smoke and fire alarm. This alarm does not require 
battery changes. It has a permanent power lithium free sealed battery backup 
which will last for approximately 10 years from the date of activation. This 
manual includes important information regarding where to install the alarm, how 
to operate, maintenance, testing and product features. It also includes tips and 
information which could help protect you and your family. This alarm detects 
products of combustion using a multi-criteria smoke and fire sensor.

TABLE OF CONTENTS

 ...............................................................

PAGE

Smoke Alarm Limitations and Functions .........................................  2
Recommended Location of Alarms ................................................... 2
Avoid These Locations ....................................................................... 3
Early Warning ..................................................................................... 4
Installation Instructions ..................................................................... 4
Electrical Shock Hazard ...................................................................... 4
Locking/Tamper Feature .................................................................... 4
Wiring Instructions ............................................................................. 5
Operation, Testing & Maintenance ................................................... 6
QUICK FIND

®

 Alarm Originating Feature ......................................... 7

Resetting ............................................................................................. 7
Cautions/Warnings ............................................................................. 7
Silence Feature ................................................................................... 7
Battery and Alarm Deactivation ........................................................ 8
Repairs and Services ........................................................................... 9
Develop and Practice a Plan of Escape ............................................. 9
Operational Summary ...................................................................... 10
Warranty  .............................................................................Back Cover

READ ALL INSTRUCTIONS

This smoke alarm uses an extremely small amount of a radioactive  

element in the ionization chamber. Do not tamper with radioactive 

sealed source or try to repair the smoke alarm yourself.

288-3648-00

©2020 UNIVERSAL SECURITY INSTRUMENTS, INC., Rev. 05/2020 CD

Printed in China

Содержание Sensing Plus AMI1061S

Страница 1: ...and your family This alarm detects products of combustion using a multi criteria smoke and fire sensor TABLE OF CONTENTS PAGE Smoke Alarm Limitations and Functions 2 Recommended Location of Alarms 2 Avoid These Locations 3 Early Warning 4 Installation Instructions 4 Electrical Shock Hazard 4 Locking Tamper Feature 4 Wiring Instructions 5 Operation Testing Maintenance 6 QUICK FIND Alarm Originating...

Страница 2: ...ould be installed inside each bedroom or sleeping area Do not obstruct airflow around the smoke alarm or place in areas of obstructed airflow BEAWARE OF VARIOUS SITUATIONSAGAINST WHICH THE SMOKEALARM MAY NOT BE EFFECTIVE For example 1 Fires where the victim is intimate with a flaming initiated fire for example when a person s clothes catch fire while cooking 2 Fires where the smoke is prevented fr...

Страница 3: ...dards Title 24 CFR Section 3280 208 and Section 3282 For additional protection see Single Story Residence smoke alarm requirements recommendations for Existing Homes and New Construction Homes Note For mobile homes built before 1978 install smoke alarms on inside walls between 4 and 12 from the ceiling older mobile homes have little or no insulation in the ceiling This is especially important if t...

Страница 4: ...e mounting bracket Page 4 Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows A smoke alarm installed in each separate sleeping area in the vicinity of but outside of the bedrooms and as appropriate heat or smoke alarms in living rooms dining rooms kitchens hallways attics furnace rooms closets utility sto...

Страница 5: ...system The following alarms can trigger Quick Find Alarm Origination but will not indicate Alarm Origination on an interconnected system USI 1204 USI 1209 USI 1213 USI 3204 USI 2430 The following alarms cannot be reset through an interconnected system because they do not have Quick Find Alarm Origination USI 1204 USI 1209 USI 3204 USI 2430 Interconnected smoke alarms heat alarms and relays will on...

Страница 6: ... the test button If the alarm sounds it has been effectively activated If the alarm does not sound after pressing the test button the alarm is not activated and will not provide protection 4 Plug the AC Quick Connector into the alarm base Push and twist the alarm clockwise onto the mounting bracket 5 See OPTIONAL TAMPER RESISTANT FEATURE and TO ACTIVATE THE LOCKING FEATURE instructions on Page 4 6...

Страница 7: ...ed and no backup battery is present NOTE Actuation of the test button must be by use of a person s finger or thumb Use of any other instrument is strictly prohibited ALARM ORIGINATION QUICK FIND Alarm Origination In an interconnected system consisting of any of these models 5304 5304L MI106 MDS107 MCN108 MICN109 MDSCN111 MP117 MI106S and MIC1509S MP116S MPC122S it may be difficult to determine whi...

Страница 8: ...assemble or attempt to clean inside the alarm This alarm contains no serviceable parts If the alarm becomes contaminated by excessive dirt or grease and cannot be cleaned it should be replaced immediately Alarms have a limited life and should always be replaced 10 years from the date of purchase AFTER CLEANING REINSTALL YOUR ALARM AND TEST YOUR ALARM BY USING THE TEST BUTTON Page 8 BATTERY AND ALA...

Страница 9: ...nce with the National Fire Protection Association s Standard 72 National Fire Protection Association Batterymarch Park Quincy MA 02269 DEVELOP AND PRACTICE A PLAN OF ESCAPE BASICS OF ESCAPE PLAN o Make a floor plan indicating all doors and windows and at least two escape routes from each room Second story windows may need a rope or chain ladder o Have a family meeting and discuss your escape plan ...

Страница 10: ...moke alarm Another interconneced smoke alarm has sensed smoke causing all interconnected units to alarm 3 Beeps 2 second pause Repeat Blinks on approx every 2 minutes Stays On If alarm sounds and hazard is identified please take all precautions by getting out of the home immediately and then calling an Emergency Service Nuisance Alarm 3 Beeps 2 second pause Repeat Blinks On in sync with horn Stays...

Страница 11: ...ned herein No implied warranty on this product created by state law shall extend beyond the term of this warranty unless such law otherwise provides USI specifically disclaims any liability and shall not be liable for any consequential or incidental loss or damage including but not limited to damages to any equipment with which this product is used Some states do not allow the exclusion or limitat...

Отзывы: