B. Main Regulator Disassembly:
1. Shut down system in accordance Section VI.
2. Disconnect external sensing line, if in stalled.
Disconnect tubing at inlet connection of the
main regulator body, the inlet and outlet of the
loader and at the outlet of main regulator.
3. Though it is possible to disassemble the valve
unit while installed in a pipeline, it is rec om-
mend ed that maintenance be done in a shop
when possible. The instructions hereafter will
assume shop disassembly. Remove main
regulator from pipeline.
4. Place the main regulator body in a vise with
the cover dome (25) upwards.
5. Loosen and remove the diaphragm flange
bolts (11) and nuts (12) uniformly. Set loading
regulator aside.
6. Place matchmarks on body (23) and cover
dome (25) flanges. Remove cover dome (25).
WARNING
SYSTEM UNDER PRESSURE. Prior to per form ing any
maintenance, isolate the reg u la tor from the system and
relieve all pressure. Failure to do so could result in
personal injury.
Tubing Connection
Check Valve
Tubing Connection
7. Hold the milled “flats” on top of the valve
plug (20) stationary, rotate the di a phragm
lock nut (7) CCW to remove.
8. Remove upper diaphragm plate (8).
9. Remove diaphragm (9) and o-ring upper stem
seal (14.1). Examine diaphragm to determine
whether failed; determine if op er at ing condi-
tions are ex ceed ing pressure, pressure drop
or temperature limits.
10. Re
move lower diaphragm plate (10).
Figure 2
Loader
Ori
fi
ce
Gauge
Filter