IOM-ALR-1

2

IV.  PRINCIPLE OF OPERATION

1.  When a loading pressure – P

Load

 – is applied to 

the top side of a diaphragm, the outlet controlled 
pressure – P

2

 – will balance at approximately        

.90 – .98 of the loading pressure - P

L

.

 (NOTE:

 

Fluc tu a tions in P

1

 – Inlet Pressure will cause a 

deviation in P

– Outlet Pressure due to inverse 

sym pa thet ic ratio effect.)  See Section VIII.

2.  Movement occurs as pressure variations register 

on the diaphragm.  The registering pressure is the 
outlet, P

2

, or downstream pressure.  The loading 

pressure fluid op pos es di a phragm move ment.  
As outlet pres sure drops, the loading pressure 
push es the di a phragm down, opening the port; as 
outlet pres sure increases, the diaphragm pushes 
up and the port opening closes.

3.  A diaphragm failure will tend to cause the reg u la tor 

to fall below setpoint. A loss of loading pres sure 
while inlet pressure is imposed will cause the  
regulator to fail close. A com plete diaphragm failure 
will cause the inlet process fluid to mix with the 
loading fluid.

V. STARTUP

1  Start with the block valves closed.

2.  Rotate the adjusting screw of the unloader CCW  

three revolutions to decrease the set point pres-
sure of the main regulator.

3.  If it is a “hot” piping system, and equipped with 

a bypass valve, slowly open the bypass valve 
to preheat the system piping and to allow slow 
ex pan sion of the piping.  Closely monitor outlet 
(down stream) pressure via gauge to ensure not 
over-pressurizing.  

NOTE: 

If no bypass valve is 

in stalled, extra caution should be used in starting 
up a cold system; i.e. do everything slowly.

4.  Crack open the outlet (downstream) block valve 

to approximately 10% full open.

5.  Slowly open the inlet (upstream) block valve to 

about 25% open. Rotate the adjusting screw on 
the unloader CW to increase the setpoint pres-
sure if necessary until the main valve is flowing. 
Observe the outlet pressure gauge to ensure not 
over pressurizing.

6.  Continue to slowly open the inlet (upstream) block 

valve until fully open.

7.  Continue to slowly open the outlet (downstream) 

block valve, especially when the downstream pip-
ing system isn’t pressurized. If the outlet (down-
 stream) pressure exceeds the desired pres sure, 
close the inlet block valve and go to Step 2. Close 
bypass valve approximately 25%, and re peat 
pro ce dure.

SECTION IV

SECTION V

            CAUTION

DO NOT HYDROSTATIC TEST THROUGH AN IN STALLED 
UNIT; ISOLATE REGULATOR FROM TEST.  The "OUTLET 
RATING" as printed on the name plate is the rec om mend ed 
“upper op er at ing limit” for the sens ing di a phragm.  Higher 
pres sures could cause internal dam age.  In ad di tion, note 
on the nameplate that the Inlet and Outlet pres sure and 
temperature ratings are at different levels.

          CAUTION

Do not walk away and leave a bypassed reg u la tor 
unattended!

Model ALR-1 - External Sense

Back Pressure
Unloader & PI

Recommended Piping Schematic

For Pressure Reducing Station

Auxiliary Air Supply

Содержание ALR-1

Страница 1: ...omenteringvalveanddamaging internal soft goods primarily the dynamic seal 4 DownstreamSensingInstallationConsiderations Internal or External Sensing a Theregulatormaybeinstalledwithinternalor external...

Страница 2: ...the piping Closely monitor outlet downstream pressure via gauge to ensure not over pressurizing NOTE If no bypass valve is installed extra caution should be used in starting up a cold system i e do e...

Страница 3: ...Static Stem Seal 15 All Cage O ring Seal 16 CW Wiper 17 1 CW Wiper Washer 17 3 UC Seal Retainer 19 All Cage 20 All Valve Plug 21 All Seat Ring 27 All Dynamic Side Seal 27 1 CW TFE Cap Seal 27 2 CW O r...

Страница 4: ...the regulator body in a vise with the cover dome 25 upwards 5 Loosen the diaphragm flange bolts 11 and nuts 12 uniformly 6 Place matchmarks on body 23 and cover dome 25 flanges Remove cover dome 25 W...

Страница 5: ...itions are exceeding pressure pressure drop or temperature limits Remove dynamic side seal 27 components Special care should be taken when using tools to remove the components to ensure that no scratc...

Страница 6: ...r lower circumference of guide bearing 13 taking care not to cut o ring energizer seal 27 2 Using thumbs work the o ring energizer seal up and into the groove of the bearing 13 NOTE A very slight amou...

Страница 7: ...he upper diaphragm plate 8 and the lower diaphragm plate 10 over the upper end of valve plug 20 and temporarily secure with diaphragm lock nut 7 manually tightened Do NOT al low valve plug 20 to rotat...

Страница 8: ...2 1 15 25 60 70 81 95 1 1 4 2 32 50 120 130 163 176 2 1 2 4 65 100 180 200 244 271 Body Size in Dn Torque Value Ft lbs N m 1 2 2 15 50 30 35 41 47 2 1 2 4 65 100 45 50 61 69 Figure 5 Location of Auxil...

Страница 9: ...w Failure to do so may result in flying parts that could cause personal injury WARNING 11 plug gasket 13 and plug 14 NOTE Refer to the quantity of diaphragms 11 incorporated per the bill of materials...

Страница 10: ...ug 14 If seat ing surface shows signs of erosion wear the seat ring 15 and plug 14 should be replaced 3 Clean body 1 cavity Clean all parts to be reused NOTE On regulators originally supplied as oxyge...

Страница 11: ...ng psig Barg LVPS psig Barg none none 0 0 0 0 2 5 14 34 3 21 2 14 1 2 07 14 1 07 1 07 4 10 28 6 9 6 41 4 28 SIZE ORIENTATION S O Factor Body Size in DN Orientation Cover Dome on Top Cover Dome on Bott...

Страница 12: ...external sensing line C Oversized regulator C Check actual flow conditions resize regulator for minimum and maxi mum flow if necessary replace with smaller regulator D Too much variation in Inlet Pres...

Страница 13: ...Material BOM a parts list that was provided when unit was originally shipped Serial Number typically 6 digits Product Code typical format as follows last digit is alpha character that reflects revisio...

Страница 14: ...illed Internal Sensing Only 99 Nameplate Not Shown Not required on 2 CS SST Body Material Recommended Repair Parts Main Regulator Assembly The contents of this publication are presented for informatio...

Страница 15: ...1 Body 2 Spring Chamber 3 Adjusting Screw 4 Lock Nut 5 Spring Button 6 Range Spring 7 Pressure Plate Nut 8 Lock Washer 9 Travel Stop 10 Pressure Plate 11 Diaphragm 12 Diaphragm Gasket 13 Plug Gasket 1...

Страница 16: ...ct leads to heating or cooling of the process gas depends on the process gas and the inlet and outlet pressures The system designer is responsible for determining whether the process gas temperature m...

Страница 17: ...DA4 DA5 DA6 DA8 DA0 DA1 DAP SAP SLR 1 SLR 2 PTR 1 ALR 1 ULR 1 PGR 1 BQ BQ OPT 45 BQ CRYO 123 123 CRYO 123 OPT 45 123 OPT 46G 123 1 6 123 1 6 OPT 45 123 1 6 OPT 46G 123 1 6 S 123 1 6 S OPT 40 1000HP 10...

Отзывы: