Please refer to this troubleshooting guide before requesting service or contacting your dealer for assistance�

TROUBLESHOOTING TIPS

This device complies with RSS-210 of Industry Canada�  Operation is subject to the following two conditions: (1) this 

device may not cause interference, and (2) this device must accept any interference, including interference that may 

cause undesired operation of the device�

1� This device complies with part 15 of the FCC Rules�  Operation is subject to the following two conditions: (1) this 

device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation�

2� This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 

15 of the FCC Rules�  These limits are designed to provide reasonable protection against harmful interference in a 

residential installation�  This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio communications�  However 

there is no guarantee that interference will not occur in a particular installation�  If this equipment does cause 

harmful interference to radio or television reception, which can be determined by turning the equipment off and 

on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient 

or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect the 

equipment into an outlet on a circuit different from that to which the receiver is connected�  Consult the dealer or 

an experienced radio/TV technician for help.  Note: Any changes or modifications to the transmitter or receiver not 

expressly approved by Casablanca Fan Company may void one’s authority to operate this remote control�

PROBLEM

POSSIBLE REMEDIES 

Fan will not start

• Check the main circuit fuses, circuit breakers, and wall switch position. Check all wire connections. 

Make sure the power is turned off during this inspection�

• Pin connectors are not making good contact. Check all connections.

• The fan receiver is defective. Replace the fan receiver.

• Reset the frequency setting:  Turn the power off at the circuit breaker for the fan that is not functioning 

only� Within 20 seconds from restoring power to the ceiling fan and the W-74 Wall Control press and hold 

both the “1” and 

1

2

0

4

3

 reverse buttons as shown in Figure #2 for 3 seconds, you will hear one tone from 

the Piezo Buzzer indicating the command has been accepted� The Fan will come on at “low” speed in the 

reverse direction�
Fan wobbles or shakes excessively

• Be sure the canopy pin is set properly into the slot on the ball.

• Check that the blade holders have not been bent during installation and the blades are balanced.

• The hanger bracket and/or the ceiling outlet are attached too loosely.  Make sure the hanger bracket is 

attached tightly to the ceiling outlet box and the downrod assembly is secured firmly� 

• The downrod is attached to the downrod base too loosely. Make sure all the screws are securely 

tightened�

• A balancing kit is supplied with the fan to remedy slight wobble problems. Check all previous steps 

before using this kit�

Fan is noisy during operation

• When changing fan speeds or reversing the fan, you may hear several audible clicks. This is normal 

operation�

• Check and tighten the light fixture retaining screws, glass shade screws, and/or lightbulb(s).

• Tighten the canopy screws and mounting plate assembly. Make sure the wire nuts inside the canopy 

and switch housing are not touching the metal parts and that they have not fallen off the wire splices� 

Tighten as necessary�

• Tighten the blade holders to the flywheel (or Direct Drive motor) and the blades to the bladeholder 

screws�

• Make sure all the screws in the motor housing are snug but not overly tight.

Fan does not run on low speed

• If fan is new, it may need to be “broken in.” Run at high speed for several days.

Light is too dim

• Make sure the dimmer setting is at the desired level.Hold the 

1

2

0

4

3

 Up or down light button to activate 

the dimmer of the fan� Release the button when the desired luminosity is reached�

Содержание Ceiling fans

Страница 1: ...Fan Installation 7 Getting Started 7 Mounting Bracket Installation 7 Pipe Scroll Hardware 8 Decorative Scroll Assembly 8 10 Ceiling Installation 9 8 Ceiling Installation 11 Hanging the Fan 12 Wiring...

Страница 2: ...Set Screw Pre Installed 33 Screw 6 32 X 62 36 Screw 6 32 X 1 5 39 Scroll 37 Shaft Collar 28 Blade Set 18 Blade Iron Hardware Pack C 27 Screw 12 X 56 Hardware Pack D 31 Blade Washer 30 Screw 10 32 X 25...

Страница 3: ...1 16 000 1 1 1 1 G0151 03 000 2 2 4 4 1 89346 02 000 1 87942 07 611 1 87942 64 611 1 76976 01 611 1 98968 07 000 1 5 5 5 1 1 G0113 36 000 5 88828 09 000 1 G0111 01 000 11 1 89440 19 000 21 21 1 G0168...

Страница 4: ...stall them Before discarding packaging materials be certain that all parts have been removed Use a clean dry paintbrush to remove small Styrofoam pieces that may remain after unpacking Do not brush St...

Страница 5: ...ing pinched WARNING Do not bend the blade brackets when installing the brackets balancing the blades or cleaning the fan Do not insert foreign objects in between the rotating fan blades Unpacking Befo...

Страница 6: ...Ceiling Angle Use the tear off Ceiling AngleTemplate card inserted in this manual It provides you with a simple go or no go for installing your fan on a sloped ceiling 7 minimum When to Use Extension...

Страница 7: ...e electrical shock or personal injury mount to outlet box marked Acceptable Fan Support of 22 7 kg 50 lbs or less using the mounting hardware provided with the outlet box or directly to structure CEIL...

Страница 8: ...64 pilot holes do not use lubricants on the screws Do not over tighten Joist Ceiling Fan Approved Wiring Box Washer Wood Screw Allen Wrench ALLEN SET SCREW pre installed Collar Decorative Scroll Screw...

Страница 9: ...Adaptor 10 CEILING INSTALLATION Step 6 Remove theTrim Ring from the Canopy Step 7 Insert the Pipe Assembly through the Canopy first andTrim Ring second Step 8 Feed the wires from the fan through the...

Страница 10: ...separate from the downrod during normal operation Set Screw Scroll to Motor Screw Step 11 Align the 5 Scroll Arm with the five holes on top of the motor Step 12 Assemble Scroll to the top of the moto...

Страница 11: ...Trim Ring Canopy and downrod Step 4 Note Make sure all the wires are on the same side of the metal dowel pin inside the dowrod Step 5 Twist the Pipe Assembly into the Motor Adapter by turning Counter...

Страница 12: ...ING THE FAN Step 1 Trim wires to about 6 from the top of the downrod Step 2 Strip 1 2 of insulation off each wire using wire strippers Raise the fan and place the ball into the hanger bracket Step 3 A...

Страница 13: ...the Hanger Bracket while you slide the Receiver into the open end of the Hanger Bracket as shown NOTE Ensure you do not tuck the bare ground wire from the ceiling back into the box This will be connec...

Страница 14: ...nnect it to the White Wire coming from the fan with a blue wire cap Step 7 Use the Red wire marked FAN OUT from the receiver and connect it to the Red Wire coming from the fan with a blue wire cap Ste...

Страница 15: ...Align the partially installed screws with the key slots in the canopy Step 12 Twist the Canopy clockwise to secure Step 13 Install the third fourth canopy screws in the round holes on Canopy Securely...

Страница 16: ...or each blade assembly Step 3 Repeat steps for all five Blades Step 4 Align the Blade Iron to 2 of the holes on the Blade Iron Adapter on the bottom of the Fan as shown in Figure 2 Step 5 For each Bla...

Страница 17: ...Plate Screws are firmly situated in the narrow end of the keyhole slots Step 4 Install the remaining screw into the Light Kit Mounting Plate Step 5 Tighten all three screws firmly Mounting Plate Screw...

Страница 18: ...ched or dirty clean carefully with a tissue A dirty glass bulb will cause the bulb to fail almost immediately Halogen Bulb 50 Watt Finial Light Kit Stem WARNING Do not touch the glass bulbs with your...

Страница 19: ...l should only be installed on Casablanca s Direct TouchTM Fans 1 Use only the Casablanca W 74 wall control 2 Do not use any additional control with your Direct TouchTM fan for example dimmer or fan sp...

Страница 20: ...ore installing the two switches into the wall place both switches side by side then locate the 6 dip switches on the side of the two switches as shown in Figure 3 Then make sure that the dip switches...

Страница 21: ...normally left in the on position Always turn the power off during cleaning or servicing the fan and during thunderstorms It is also used to exit or enter additional programs The 1 2 0 4 3 power butto...

Страница 22: ...e 1 2 0 4 3 power button 6 Allow the fan to remain off for at least 5 seconds 7 Press the power button again to restore power to the fan 8 Immediately press and hold the 2 and 4 buttons for at least 5...

Страница 23: ...ogram 1 Turn the 1 2 0 4 3 power button off for at least 5 seconds This will clear the fan memory ready for programming 2 Turn the 1 2 0 4 3 power button on 3 Immediately hold the 0 button for at leas...

Страница 24: ...turn off after 2 hours 3 The fan will respond with three descending tones A timer is now initiated and the fan will reduce one speed for each two hour interval The fan will not however descend below t...

Страница 25: ...witch position Check all wire connections Make sure the power is turned off during this inspection Pin connectors are not making good contact Check all connections The fan receiver is defective Replac...