20
1
2
0
4
3
1.
To control the fan and lights from two
locations (a three-way circuit), use two W-74
wall controls�
2.
Remove the screws and switch plate from the
existing switch box and the screws holding
the switch in the switch box� Figure #5
3.
Pull the existing switch from the switch box to
expose the wire connections�
4.
Determine which wire is connected to the
common terminal from the power source
(120V AC) of the three-way switch. (The
terminal will be marked on switch)�
5.
Remove the wire from the common terminal
of the three-way switch� Connect this wire to
the remaining black/white striped wire on the
W-74 control� Secure this splice with a wire
nut� Figure 4
CAUTION!
Ensure power is turned OFF at the breaker or fuse panel before starting installation�
DUAL W-74 INSTALLATION
BLACK
BLACK
RED
GREEN
120V AC
BLACK
BLACK WITH
WHITE STRIPE
W-74
RED
RED
RED
BLACK WITH
WHITE STRIPE
GREEN
W-74
BLACK
BLACK
BLACK
BLACK
BLACK
NEUTRAL
WHITE
GREEN
To control the fan and lights from two locations (a three-way
circuit), use two W-74 wall controls as shown in the wiring diagram
in Figure #4� Before installing the two switches into the wall, place
both switches side by side, then locate the 6 dip switches on the
side of the two switches as shown in Figure #3� Then make sure that
the dip switches are set to the same address on both switches as
shown in Figure #3� When setting these dip switches you are setting
the channel number that is required to control both your fan and
lights from both sides of the room� If you are installing other Direct-
Touch
TM
3 fans within your home you may need to reset the dip
switches on these other fans to a different channel before installing
your W-74 wall control into the wall� Please review the section on
channel changing within this part of the operation manual as shown
on page #22�
DIP SWITCHES
Figure 3
Figure 4
2 BLACK
WIRES
BLACK AND WHITE
STRIPED WIRE
NOTE: The RED wire is not used in this
application� DO NOT remove the crimped
cap from the wire�
W-74
Wall Control
RED WIRE
NOT USED
8.
Connect the green ground wire coming
from the back of the W-74 control to the
ground wire in the switch box� Secure
the splice with a wire nut�
9.
Check your work by using the wiring
diagrams as shown in Figures # 1 and #2�
10.
Install the W-74 in the wall box with the
two long screws provided�
11.
Install the wall plate with the two white
screws�
Figure 2