V

icente

Circuit Breaker

(Trip breaker for the

circuit you will be

working on)

Fuse Box

(Remove fuse for the

circuit you will be

working on)

18"  

70" 

SAFE USE

• CAUTION: RISK OF ELECTRICAL SHOCK!  Installation is to be in accordance with the National Electrical 

Code, ANSI/NFPA 70-1999 and local codes� If you are unfamiliar with the wiring codes, you should use 
a qualified electrician�  To avoid overheating and possible damage to other equipment, do not install 
control to a receptacle, fluorescent light fixture, motor-operated appliance, or transformer-supplied 
appliance�

• This fan is designed to be installed on an existing electrical outlet box. The outlet box must be UL Listed 

for ceiling fan installations� If it is not, a new box must be installed� Casablanca extension poles are 
available for sloped or high ceiling installations�

• This ceiling fan requires a grounded electrical supply of 120 VAC, 60 Hz and a minimum 15 amp circuit. 

The maximum current requirement for the fan with light fixture is 2�9 amps� The fan uses about 1 amp 
or 100 watts� Maximum light current is 1�5 amps or 175 watts of lighting�

• Where wire nuts are employed, be sure all bare wires are within the connectors. When installing the 

canopy, make sure all wires are within the canopy and that no wires are being pinched�

WARNING: Do not bend the blade brackets when installing the brackets, balancing the blades, or 

cleaning the fan� Do not insert foreign objects in between the rotating fan blades�

Unpacking

Before assembling and installing your ceiling fan, remove all parts from the shipping cartons and check 
them against the parts listed in the Parts Guide� Before discarding packaging materials, be certain that all 
parts have been removed�

For best performance and for your warranty to be valid, use only genuine Casablanca blades, light 
fixtures, and accessories�

INTRODUCTION

•  The blades in each pack are matched for equal 

weight to assure smooth fan operation� If more 
than one fan is being installed, be careful not to 
mix blades from different cartons�

•  Inspect the contents of your carton for possible 

shipping or handling damage� If parts are missing 
or damaged, call 1-888-227-2178�

•  It is always a good idea to have an assistant to 

help with the installation�

•  When cleaning, painting, or working near your 

fan, be very careful of the fan and blades� Always 
turn the power OFF to the ceiling fan before 
working on it or replacing lightbulbs� 

•  Never insert anything into the path of the fan 

blades while the fan is in operation�

•  Never install a fan over a pool or spa. 
•  Never operate a fan that has been damaged in 

any way� Contact Casablanca Fan Company by 
calling  
1-888-227-2178, or contact your local authorized 
Casablanca dealer for assistance in obtaining 
service�

BEFORE YOU START

84"

Содержание Ceiling fans

Страница 1: ...Fan Installation 7 Getting Started 7 Mounting Bracket Installation 7 Pipe Scroll Hardware 8 Decorative Scroll Assembly 8 10 Ceiling Installation 9 8 Ceiling Installation 11 Hanging the Fan 12 Wiring...

Страница 2: ...Set Screw Pre Installed 33 Screw 6 32 X 62 36 Screw 6 32 X 1 5 39 Scroll 37 Shaft Collar 28 Blade Set 18 Blade Iron Hardware Pack C 27 Screw 12 X 56 Hardware Pack D 31 Blade Washer 30 Screw 10 32 X 25...

Страница 3: ...1 16 000 1 1 1 1 G0151 03 000 2 2 4 4 1 89346 02 000 1 87942 07 611 1 87942 64 611 1 76976 01 611 1 98968 07 000 1 5 5 5 1 1 G0113 36 000 5 88828 09 000 1 G0111 01 000 11 1 89440 19 000 21 21 1 G0168...

Страница 4: ...stall them Before discarding packaging materials be certain that all parts have been removed Use a clean dry paintbrush to remove small Styrofoam pieces that may remain after unpacking Do not brush St...

Страница 5: ...ing pinched WARNING Do not bend the blade brackets when installing the brackets balancing the blades or cleaning the fan Do not insert foreign objects in between the rotating fan blades Unpacking Befo...

Страница 6: ...Ceiling Angle Use the tear off Ceiling AngleTemplate card inserted in this manual It provides you with a simple go or no go for installing your fan on a sloped ceiling 7 minimum When to Use Extension...

Страница 7: ...e electrical shock or personal injury mount to outlet box marked Acceptable Fan Support of 22 7 kg 50 lbs or less using the mounting hardware provided with the outlet box or directly to structure CEIL...

Страница 8: ...64 pilot holes do not use lubricants on the screws Do not over tighten Joist Ceiling Fan Approved Wiring Box Washer Wood Screw Allen Wrench ALLEN SET SCREW pre installed Collar Decorative Scroll Screw...

Страница 9: ...Adaptor 10 CEILING INSTALLATION Step 6 Remove theTrim Ring from the Canopy Step 7 Insert the Pipe Assembly through the Canopy first andTrim Ring second Step 8 Feed the wires from the fan through the...

Страница 10: ...separate from the downrod during normal operation Set Screw Scroll to Motor Screw Step 11 Align the 5 Scroll Arm with the five holes on top of the motor Step 12 Assemble Scroll to the top of the moto...

Страница 11: ...Trim Ring Canopy and downrod Step 4 Note Make sure all the wires are on the same side of the metal dowel pin inside the dowrod Step 5 Twist the Pipe Assembly into the Motor Adapter by turning Counter...

Страница 12: ...ING THE FAN Step 1 Trim wires to about 6 from the top of the downrod Step 2 Strip 1 2 of insulation off each wire using wire strippers Raise the fan and place the ball into the hanger bracket Step 3 A...

Страница 13: ...the Hanger Bracket while you slide the Receiver into the open end of the Hanger Bracket as shown NOTE Ensure you do not tuck the bare ground wire from the ceiling back into the box This will be connec...

Страница 14: ...nnect it to the White Wire coming from the fan with a blue wire cap Step 7 Use the Red wire marked FAN OUT from the receiver and connect it to the Red Wire coming from the fan with a blue wire cap Ste...

Страница 15: ...Align the partially installed screws with the key slots in the canopy Step 12 Twist the Canopy clockwise to secure Step 13 Install the third fourth canopy screws in the round holes on Canopy Securely...

Страница 16: ...or each blade assembly Step 3 Repeat steps for all five Blades Step 4 Align the Blade Iron to 2 of the holes on the Blade Iron Adapter on the bottom of the Fan as shown in Figure 2 Step 5 For each Bla...

Страница 17: ...Plate Screws are firmly situated in the narrow end of the keyhole slots Step 4 Install the remaining screw into the Light Kit Mounting Plate Step 5 Tighten all three screws firmly Mounting Plate Screw...

Страница 18: ...ched or dirty clean carefully with a tissue A dirty glass bulb will cause the bulb to fail almost immediately Halogen Bulb 50 Watt Finial Light Kit Stem WARNING Do not touch the glass bulbs with your...

Страница 19: ...l should only be installed on Casablanca s Direct TouchTM Fans 1 Use only the Casablanca W 74 wall control 2 Do not use any additional control with your Direct TouchTM fan for example dimmer or fan sp...

Страница 20: ...ore installing the two switches into the wall place both switches side by side then locate the 6 dip switches on the side of the two switches as shown in Figure 3 Then make sure that the dip switches...

Страница 21: ...normally left in the on position Always turn the power off during cleaning or servicing the fan and during thunderstorms It is also used to exit or enter additional programs The 1 2 0 4 3 power butto...

Страница 22: ...e 1 2 0 4 3 power button 6 Allow the fan to remain off for at least 5 seconds 7 Press the power button again to restore power to the fan 8 Immediately press and hold the 2 and 4 buttons for at least 5...

Страница 23: ...ogram 1 Turn the 1 2 0 4 3 power button off for at least 5 seconds This will clear the fan memory ready for programming 2 Turn the 1 2 0 4 3 power button on 3 Immediately hold the 0 button for at leas...

Страница 24: ...turn off after 2 hours 3 The fan will respond with three descending tones A timer is now initiated and the fan will reduce one speed for each two hour interval The fan will not however descend below t...

Страница 25: ...witch position Check all wire connections Make sure the power is turned off during this inspection Pin connectors are not making good contact Check all connections The fan receiver is defective Replac...

Страница 26: ...finish Blades The blades on this fan have been treated with Casablanca s Dust Armor protection making the blades less likely to attract dust and dirt Use a dry or slightly damp lint free cloth to clea...

Отзывы: