Communications Manual Rev 3.21
Software Versions 3.xx
Page 32
003R-618-321
9.3. Example
Figure 8 below, demonstrates the use of the streaming registers. In this example,
REG_STREAM_REG1 contains the value 0003
H
. Looking up this index into the list
of registers yields REG_SYSTEM_ERROR. So the 1
st
position in
REG_STREAM_DATA is filled in with the contents of REG_SYSTEM_ERROR.
Similarly, REG_STREAM_REG2 contains 0004
H
, which refers to
REG_ABSOLUTE_MVV. So the 2
nd
position in REG_STREAM_DATA is filled in
with the contents of REG_ABSOLUTE_MVV. The 3
rd
position in
REG_STREAM_DATA is filled in with the contents of
REG_ADC_SAMPLE_NUMBER.
Figure 8: Streaming Registers Example
Read Stream Register
Final
20110040:
Response
81110040:000000000000123400000001
Read Stream Register
Literal
20050040:
Response
81050040:E0000,0.4660,1