![CAS X320 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/cas/x320/x320_manual_2565962024.webp)
Communications Manual Rev 3.21
Software Versions 3.xx
003R-618-321
Page
23
5.3.6. Read Items
This command reads one item from the list for the register. The item to be read is
given as a parameter to the command. Each value is returned as a string.
Command: CMD_READ_ITEM
Valid Types:
TYPE_OPTION, TYPE_MENU, TYPE_BITFIELD
Parameter: RangeMin
≤
parameter
≤
RangeMax
Return: String
value
Error Code:
If no parameter is present, the indicator returns
ERR_BAD_PARAMETER.
eg. Read items 0 and 1 from REG_DECIMAL_PLACES
Read item 0
200D0128:0
Response
810D0128:000000
Read item 1
200D0128:1
Response
810D0128:00000.0