8 System Options
27
CPD, where CZP = Calibrated Zero Point in counts, IZR is the Initial Zero Range value, & CPD is a
conversion factor called Counts Per Division.
ReZero Range: This is an allowable range from Initial Zero that the scale will go to zero from when you
press the ZERO key. The range is IZ + ((CAPACITY x RZR) / 100) x CPD, where IZ = Initial Zero Point in
counts, RZR is the ReZero Range value, & CPD is a conversion factor called Counts Per Division.
NOTE: Any changes made here will affect the NTEP Audit Trail counters (OPT counter only.)
8.1.4
Captions & Headings
For changes to Captions or Headings please consult your Authorized CAS Dealer. These changes are
only possible through Service Programming:
< SET: CAPTIONS & HEADINGS >
1.LABEL CAPTIONS
2.DISPLAY HEADINGS
The Label Captions options allow you to specify some of the Captions that get printed. An example of
a Caption is “TOTAL PRICE $” which usually appears above the Total Price box on some formats. These
need to change dynamically when toggling between weighing units (lb/kg).
The Display Headings options allow you to specify some of the wording that appears on the
REG/MGR/RPK display. These include “TOTAL PRICE $” , “PRICE lb/$”, etc. These too need to change
dynamically when toggling between weighing units (lb/kg).