background image

 

BX-Series Checkweighing Floor Scale 

Side A 

TM 

 

Installation & Assembly 

 

 

 

 Models 

 Capacities 

 

 

 

BX-120+

 120  x  0.02 lb

 

BX-150

 150 x 

 

0.05 

lb 

 

BX-300+

 300  x  0.05 lb 

 

BX-300

 300 x 

 

0.1 lb 

 

BX-600+

 600  x  0.1  lb 

 

BX-600

 600 x 

 

0.2 lb 

 

 

Pole & Display:  

Assembly of the pole display is required.  

Please follow the Assembly Instructions on Side B: 

1. Insert load cell cable through pole and insert pole 

into the bottom bracket.  Tighten all screws. 

2. Attach the top bracket to the Display Head and feed 

the load cell cable through the top bracket and 
connect it to the back of the Display Head. 

3. Tighten all screws and adjust the Display Head. 
4. Remove the Lock Bolt from underneath the platform. 

Initial Setup:

  Plug the AC adapter cable into the rear of 

the display head and then the adapter into an AC outlet.  
Some units have a fixed AC Cord instead of an adapter. 

On/Off Key:

  The 

On/Off

 Key must be held down for 

more than one second in order to turn the scale ON. 

Operating the Scale 

Make sure the platter is sitting properly on top of the 
platform and that there is nothing on top of the platter. 
Also, make sure that the scale is plugged into the proper 
outlet.  Hold down 

 

 

 until the scale display begins to 

show the self test and then release the key.  This is the 
Initial State and displays appear like this: 

   

 

The number of zeroes and decimal places may vary 
depending on model and capacity. 

Simple Weighing: 

1. Place an item on the platter 
2. The Stable Lamp will indicate a stable weight 
3. Remove the item from the platter 

Weighing Using Tares: 

1. Place the empty container on the platter 
2. Press 

 

 

 and then place an item on the platter 

3. The Stable Lamp will indicate a stable weight 
4. Remove the item from the platter 

Once you press 

 

 

, you will notice that the NET Lamp

will come on indicating to you that the weight shown is a 
net weight.  For example, this is what the display would 
look like after you press 

 

 

   

 

However, after Step 4 the display may look like this: 

   

 

In this example, the platter is empty and the tare was set 
using an empty container that weighs 2.50 pounds. 

Clearing Tares: 

1. Make sure that there is nothing on the platter 
2. Press 

 

 

 and the display will show: 

   

 

You are back to the Initial State. 

Using the Unit Key: 

1. Press 

 

 

 and the weighing units will change 

2. Repeat Step 1 until you reach the units you desire* 

You can use the 

 

 

 key in combination with/without tares 

or with/without any weight on the platter.  The scale offers 
the following units:  Pounds (lb), Ounces (oz), Kilograms, 
(kg), Grams (g), Counting (Pcs), Percentage (%), and 
Pound-Ounce (lb oz). 

*Note

 however that Counting, 

Percentage, and Pound-Ounce are 

not

 to be used in Legal 

for Trade applications. 

Counting and Percentage Weighing: 

1. Follow Unit key instructions to get to 

Pcs

 or 

%

 units 

2. Press and hold down 

 

 

 until the display shows: 

   

 

3. Release  the 

 

 

 key. You can select to sample with 

10, 20, 50, 100, or 500 pieces* by using the 

 

 

 key. 

4. Place the indicated number of piece on the platter and 

then press 

 

 

.  The scale will show Pcs or % values. 

*Note

 that when using Percentage, the scale will sample 

with 10, 20, 50, 100, or 500 %.  

Using the Mode Key: 

1. Press 

 

 

 and the weighing units will change 

2. Repeat Step 1 until you reach the mode you desire* 

You can use the 

 

 

 key in combination with/without tares 

or with/without any weight on the platter.  The scale offers 
the following modes:  Weighing1, Weighing2, Limit, and 
Hold. 

*Note

 however that Weighing2 and Hold modes are 

not

 to be used in Legal for Trade applications. 

Charging the Battery 

The 

 Lamp is located on the top left side of the display.  

When it turns ON you need to recharge the battery.  The 
scale can be ON or OFF when recharging so long as it is 
plugged into an AC outlet.  The Recharge LED is located 
above the 

 

 

 key and shows various states which are 

explained on the other side of this guide.  An overnight 
charge of 12 hours, will yield approximately a 90% charge 
or about 90 hours of continuous use (no-backlight.) 
 
 

Отзывы: