n
FUNCTION : Setting Weight In Span Calibration
RANGE
8
1~Maximum capacity of CAL 1
KEY
DISPLAY
DESCRIPTION
SET
key : store and
move into next menu
ZERO
key, , :
change the set value
CAL 3
Maximum capacity of
CAL1(ex:5000)
Setting weight(ex:500)
CAL 3 condition
5000 kg
500kg
4
Note 1. The setting weight shall be within the range of 10 % ~100 % of maximum
weight.
Note 2. If the Setting Weight is under the 10% of the Maximum Capacity,
Error message
ERR 22
will occur.
Note 3. If the Setting Weight over the Maximum Capacity,
Error message
ERR 23
will occur.
Note 4. If you press Set key, it will be moved to test 4.
CAL 4
n
FUNCTION : Zero Calibration
KEY
DISPLAY
DESCRIPTION
SET key :
Zero calibration
CAL 5
LOAd
setting weight
checking - 333333
indicator 222222
111111
GOOd
Factor value
End
CAL 4 condition
Unload the tray and press SET
Display A/D Value
Under zero calibration
Zero calibration is completed.
The program moves into Span
calibrayion automatically.
4
Note 1. If Zero calibration is done without any error, GOOD message is displayed
and program moves into CAL 5 automatically.
Note 2. If the zero value is too low, ERROR message
ERR 27
is displayed.
Note 3. If the zero value is too high, ERROR message
ERR 26
is displayed.
Note 4. Zero calibration can be done independently. If you press
ZERO
key instead
of
SET
key, zero calibration will perform.
CAL 5
n
FUNCTION : Span Calibration
4
Note 1. If Span calibration is done without any error, GOOD message is
displayed. The weight of setting weight is displayed on VFD screen.
Check the weight.
Note 2. If the span value is low, Error message
ERR 24
is displayed.
If the span value is high, Error message
ERR 25
is displayed.
In that case, calibrate with lower resolution.
Please check the span value to be resolution 4 in TEST 3.
Note 3. If you press
SET
key, it will be moved to NORMAL MODE.
KEY
DISPLAY
DESCRIPTION
SET key :
Span calibration
CAL 5
LOAd
setting weight
checking - 333333
indicator 222222
111111
GOOd
Factor value
End
CAL 5 condition
Load the weight which was set in
CAL 3
It is displayed the setting weight.
And then, press Set key.
Under span calibration.
Span calibration is completed.
Check whether the displayed
weight is same with setting
weight.
The weight converting constant
value
Calibration is completed.
Under this condition, release the
load.
◀ ▲