23
22
F07
Function
Display
Description
Weight backup
(OFF, ON)
F07 0
weight backup is off
F07 1 weght backup is on
4
Note 1. In case occurring sudden power failure, it can be memoried the moment
value by this function
Note 2. If the AC power is OFF suddenly and weight backup is ON, the scale
recovers previous weight after the power is ON.
Note 3. On and Off are alternately displayed by pressing the numeric keys.
F08
Function
Display
Description
External Input 2
Usage(0~3)
F08 0
Tare Key
F08 1
Print Key
F08 2
Hold Key
F08 3
Start Key in Realy Mode
4
Note. This function is available to control in long disitance.
At this time, you can adjust key usage fit for the purpose.
F09
Function
Display
Description
Zero key op
F09 0
4% : zero key opearation within 4%
of maximum weight
F09 1 10% : zero key opearation within
10% of maximum weight
4
Note. This function is to set the range of initial zero value.
F10
Function
Display
Description
Device number
(Identifcation
number of each
indicator, 00~99)
F10 00
Device No. 00
F10 05
Device No. 05
4
Note 1. This device number is the data demanding signal in serial communication.
Note 2. It shall be in 2 in F03.
F11
Function
Display
Description
Baud rate
(Unit of speed In
data transmission,
0~5)
F11 0
600bps(bit per second)
F11 1
1200bps
F11 2
2400bps
F11 3
4800bps
F11 4
9600bps
F11 5
19200bps
4
Note. It shall be just in 2 of F03.
F12
Function
Display
Description
Data set send to
computer (0~3)
F12 0
No data out put
F12 1
Transmission in state of stable or
unstable
F12 2
Transmission only in stable state
F12 3
Transmission only when requiring
data
4
Note 1. When the scale is shipped out, the setting value is 0.
Note 2. In case of setting 3 of F12, weighing data will be transmitted after receiving
one byte which is specified in F10
Note 3. It shall be just in 2 of F03.
F13
Function
Display
Description
Hold type set (0~2)
F13 0
Average Hold
F13 1 Peak Hold
F13 2
Sampling Hold
4
Note. Average hold : Compute the average weight of oscillating weights.
Peak hold : Compute the maximum weight of oscillating weights.
Sampling hold: Compute the moment weight of oscillating weights.
F14
Function
Display
Description
Clock usage (0~1)
F14 0
Not using Clock
F14 1 Using Clock