CAS 1560A Скачать руководство пользователя страница 13

27

26

n

Limit  Mode

                                     (LOW limit)          (HIGH limit)
              0 kg                    50 kg                  100 kg

WEIGHT

RELAY

ZERO

(OUT RELAY 1)

 ON

 OFF
 ON

 OFF
 ON

 OFF

 ON

 OFF

 ON

 OFF
 ON

 OFF
 ON

 OFF

 OFF

 ON

LOW

(OUT RELAY 2)

HIGH

(OUT RELAY 3)

FINAL

(OUT RELAY 4)

4

Note.  When L-FALL and H-FALL are set,

               Low limit relay will come ON (Weight = Lo - L-FALL).
               High limit relay will come ON (Weight = HI - H-FALL).

n

Checker  Mode

                                     (LOW limit)          (HIGH limit)
              0 kg                    50 kg                  100 kg

WEIGHT

RELAY

 ON

 OFF

 ON

 OFF
 ON

 OFF
 ON

 OFF

ZERO

(OUT RELAY 1)

LOW

(OUT RELAY 2)

HIGH

(OUT RELAY 3)

FINAL

(OUT RELAY 4)

n

Limit  Type  Checker  Mode

n

Paker  Mode

                                     (LOW limit)          (HIGH limit)
              0 kg                    50 kg                  100 kg

WEIGHT

RELAY

ZERO

(OUT RELAY 1)

LOW

(OUT RELAY 2)

HIGH

(OUT RELAY 3)

FINAL

(OUT RELAY 4)

relay on at

stable

Содержание 1560A

Страница 1: ...N 6 FEATURES 6 TECHNICAL SPECIFICATION 7 MEASURE OF APPEARANCE 8 FRONT PANEL 9 REARPANEL 10 INSTALLATION CONNECTION 11 TESTMODE 13 CALIBRATIONMODE 16 SETMODE 20 WEIGHINGMODE 28 RS 232CINTERFACE CLOCK 32 ERROR MESSAGEAND TROUBLESHOOTING 36 ...

Страница 2: ...den temperature changes n This scale must be installed in a dry and liquid free environment n Do not severely press because the light pressing of keys can incite the operation n Do not use inflammable materials in cleaning n Keep the scale away from strong EMI noises may cause incorrect weight reading ...

Страница 3: ... power failure n Adjustable display rate Digital filter function n Tare weight setting with keys n Users can set maximum weight which users want to and division at one s disposal n Self test hardware function n Independent zero calibration n External Input Output CI 1560A 2 External Input zero F08 4 External Output zero 1 Step 2 Step Final n Serial printer connection n Print date and time by inner...

Страница 4: ...n this key is pressed the scale stores current weight as the tareweight If you press TARE key in unload condition tare setting is released Used to enter the SET mode Used to current value X 10 in CAL SET mode Use this key to switch from GROSS to NET weight The annunciators and display will alternate between GROSS and NET aswell In case tare weight is REGISTERED tare plus item s weight is GROSS wei...

Страница 5: ...ield n Connecting method 4Each L C manufacturer sor model s wire color could be different In that case please note the following diagram n Manufacturer s wire color Connector Company Pin 1 EX Pin 3 EX Pin 5 SIG Pin 6 SIG Pin 7 SHIELD CAS RED WHITE GREEN BLUE CASE KYOWA RED BLACK GREEN WHITE CASE INTERFACE RED BLACK GREEN WHITE CASE P T RED BLACK GREEN WHITE CASE BLS GREEN BLACK WHITE RED YELLOW SH...

Страница 6: ...COM KEY IN PUT COM TEST MODE n How to enter Turn on the power while pressing the ZERO key on the front of the indicator 4When test is done Press SET key n Available keys Set key Used for moving to the next test menu Other keys Used for changing the preset value n Test Menu TEST 1 TEST 6 TEST 1 Key test TEST 2 Display test TEST 3 Load cell test and A D conversion test TEST 4 Serial interface test T...

Страница 7: ...ode and F03 is 2 in SET mode KEY DISPLAY DESCRIPTION SET to next menu Other keys Transmitting key Waiting for transmission and reception Transmitted none Received 1 Transmitted 1 Received none Transmitted 1 Received 1 INDICATOR TEST When it isn t connected with PC Conect directly between No 2 TXD and No 3 RXD in indicator of serial port If transmitting data is identical with receiving data by pres...

Страница 8: ...n Menu CAL 1 CAL 7 CAL 1 Maximum Capacity Set CAL 2 Minimum Division Set CAL 3 Setting Weight in Span Calibration CAL 4 Zero Calibration CAL 5 Span Calibration CAL 1 n FUNCTION Maximum Capacity Set RANGE 8 1 999 999 KEY DISPLAY DESCRIPTION SET key store and into next menu ZERO key change the set value t1 00 CAL 1 Maximum capacity value ex 5000 Program version CAL 1 condition 5000 kg 4Note 1 The ma...

Страница 9: ...m moves into CAL 5 automatically Note 2 If the zero value is too low ERROR message ERR 27 is displayed Note 3 If the zero value is too high ERROR message ERR 26 is displayed Note 4 Zero calibration can be done independently If you press ZERO key instead of SET key zero calibration will perform CAL 5 n FUNCTION Span Calibration 4Note 1 If Span calibration is done without any error GOOD message is d...

Страница 10: ...al data print F02 2 is Start key in relay mode F03 Function Display Description Serial Port usage 0 2 F03 0 Not Used F03 1 Connection to Serial Printer F03 2 Connection to P C or RemoteDisplay F04 Function Display Description Automatic print 0 1 F04 0 Manual print whenever you press the key it will be printed F04 1 Automatic print when the weight is stable or you press the key it will be printed F...

Страница 11: ...evice No 00 F10 05 Device No 05 4Note 1 This device number is the data demanding signal in serial communication Note 2 It shall be in 2 in F03 F11 Function Display Description Baud rate Unit of speed In data transmission 0 5 F11 0 600bps bit per second F11 1 1200bps F11 2 2400bps F11 3 4800bps F11 4 9600bps F11 5 19200bps 4Note It shall be just in 2 of F03 F12 Function Display Description Data set...

Страница 12: ...y 00 12 C2 10 October C3 Function Display Description Set Day 00 31 C3 30 Day 30 C4 Function Display Description Set Hour 00 23 C4 15 P M 3 C5 Function Display Description Set Minute 00 59 C5 59 Minute 59 C6 Function Display Description Set Second 00 59 C6 39 Second 39 F20 Function Display Description RELAY MODE USAGE 0 4 F20 0 Not used F20 1 Limit Mode F20 2 Checker Mode F20 3 Limit type Chcker M...

Страница 13: ...Low limit relay will come ON Weight Lo L FALL High limit relay will come ON Weight HI H FALL n Checker Mode LOW limit HIGH limit 0 kg 50 kg 100 kg WEIGHT RELAY ON OFF ON OFF ON OFF ON OFF ZERO OUT RELAY 1 LOW OUT RELAY 2 HIGH OUT RELAY 3 FINAL OUT RELAY 4 n Limit Type Checker Mode n Paker Mode LOW limit HIGH limit 0 kg 50 kg 100 kg WEIGHT RELAY ZERO OUT RELAY 1 LOW OUT RELAY 2 HIGH OUT RELAY 3 FIN...

Страница 14: ...ompensation Display or Key On platform Description step 1 Empty Zero point drift step 2 Press ZERO key when the weight is stable step 3 Empty ZERO Compensation The present value is returned the display to the ZERO 4Note 1 It shall be in zero range to 4 or 10 of maximum capacity in Set Menu of F09 Note 2 Non ability in HOLD state of the weight Note 3 Non ability in setting tare n Example 2 Tare Fun...

Страница 15: ...g condition HOLD will release step 5 Unload When it is became unloading condition HOLD will release automatically 4Note 1 Choose HOLD type in SET menu F13 Average HOLD F13 0 Compute the average weight of oscillating weights Peak HOLD F13 1 Choose the maximum weight among oscillating weights Sampling HOLD F13 2 Choose the current weight of oscillating weights Note 2 In case of using external input ...

Страница 16: ... over load GS gross NT net Device ID Lampstatus byte Blank Simple communication program BASIC 10 OPEN COM1 9600 N 8 1 As 1 20 IF LOC 1 0 THEN 60 30 A INPUT 1 1 40 PRINT A 50 GO TO 20 60 B IN KEY IF B THEN 20 70 PRINT B 80 PRINT 1 B 90 GO TO 20 Simple communication program C include bios h include conio h define COM1 0 define DATA_READY 0x100 define TRUE 1 define FALSE 0 define SETTINGS 0x80 0x03 0...

Страница 17: ... Male RS 232C port of CI 1560A 9 pin port Female Serial port of computer n Sub display connection RXD 3 ㅇ TXD 2 ㅇ GND 7 ㅇ ㅇ 2 Transmit Data ㅇ 3 Receive Data ㅇ 7 Signal Ground 9 pin port Male RS 232C port of CI 1500A 9 pin port Male RS 232C port of sub display RXD 3 ㅇ TXD 2 ㅇ GND 7 ㅇ ㅇ 9 Transmit Data ㅇ 5 Receive Data ㅇ 1 Signal Ground n CAS TOP printer connection P 202 9 pin port Male RS 232C port...

Страница 18: ...OUBLE SHOOTING 1 In Weighing Mode ERR 02 n Reason Load cell connection failure or error in A D conversion part n Trouble shooting Check the Load Cell connector to see if the polarity of signal is reversed ERR 13 n Reason Zero range deviate from the set range n Trouble shooting Confirm that there is nothing on the weighing platform If nothing exist do Calibration in CAL mode ERR 22 n Reason Setting...

Отзывы: