69
7. Specifications
MODEL
LP-1000
CAPACITY RESOLUTION
TARE
WEIGHT DISPLAY
UNIT PRICE DISPLAY
TOTAL PRICE DISPLAY
CONDITIONS:
TEMPERATURE RANGE
POWER
MEMORY
CAPACITY
INGREDIENT DATA
LABEL TYPES
COMMODITY NAME
DIRECT PLU KEYS
30.00 Lbs x 0.01 Lbs (15.000 kg x 0.005kg)
-30.00 Lbs ~ 0.01 Lbs (-5.99 kg ~ 0.005kg)
4 DIGITS (USA)
4 DIGITS (USA)
4 DIGITS (USA)
5 DIGITS (EX - USA)
6 DIGITS (EX - USA)
7 DIGITS (EX - USA)
85 VAC ~ 265 VAC 50/60 Hz ± 3 Hz
22°F ~ 95°F (-5°C ~ 35°C)
4000 PLU’S
1000 MSG’S
400 CHARACTERS
58 x 30mm (#8000)
58 x 40mm (#8010)
58 x 60mm (#8020)
58 x 50mm (#8030)
58 x 60mm (#8040)
2 LINES OF 28 CHARACTERS EACH = 56
CHARACTERS PER COMMODITY
54 PRESET KEYS
8. Troubleshooting
PROBLEMS
REMARKS
• Scale does not work at all.
• No light on the display & the power
switch is ON.
• Scale counts up to 9’s & then
goes blank.
• Scale counts up to 9’s & then shows:
“Zero rAnGE Error”
• Scale does not accept Tare.
• In spite of pressing the TARE key,
the Tare does not clear.
• After pressing the PRT/* button, scale
does not work at all.
• Check the fuse located to the left of the power switch.
• Try plugging scale into a different electrical outlet.
• Remove everything from the platter. Turn scale OFF and then ON.
• Make sure platter is properly installed and nothing is
obstructing the platter from underneath.
• Call your CAS Dealer for SPAN calibration.
• Make sure that the Tare being entered is within 0.01~30.00 Lbs.
• Make sure that the NET lamp is off before trying to enter a Tare.
• Make sure all items are removed from the platter & then try again.
• Remove all items from the platter and then turn the scale OFF & ON.
• Check the PEEL Sensor.