background image

2

1)

Read these instructions.

2)

Keep these instructions.

3)

Heed all warnings.

4)

Follow all instructions.

5)

Do not use this apparatus in or near water.

6)

Clean only with a dry cloth.

7)

Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8)

Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.

9)

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the
other. A grounding- type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your
safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit

from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.
12) Unplug this apparatus during lightning storms or when unused for long periods of time.
13) Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has been damaged in any way, such as

power supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally or has been dropped.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.

TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. 
NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

FCC COMPLIANCE NOTICE

:  This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1)

This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that
may cause undesired operation.  

CAUTION

:  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to

operate the equipment.

NOTE

:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC

Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

IMPORTANT

:  ZR Series amplifiers require Class 2 output wiring.

MAGNETIC FIELD 
CAUTION!

Do not locate sensitive high-gain equipment such as preamplifiers or tape decks directly above or below the unit. Because this

amplifier has a high power density, it has a strong magnetic field, which can induce hum into unshielded devices that are located
nearby. The field is strongest just above and below the unit.  If an equipment rack is used, we recommend locating the amplifier(s) in
the bottom of the rack and the preamplifier or other sensitive equipment at the top.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE
THE COVER. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED PERSONNEL!

The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the
user to the presence of uninsulated “dangerous voltage” within the products’ enclosure that may
be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user of the presence of
important operating and maintenance (servicing) instructions in the literature accompanying the
appliance.

EXPLANATION OF
SAFETY SYMBOLS

IMPORTANT SAFETY INSTRUCTIONS

Содержание ZR1000

Страница 1: ...USER MANUAL ZR1000 ZR1600 Power Amplifiers...

Страница 2: ...uipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Страница 3: ...AND STATUS INDICATORS 6 Front Panel 6 Rear Panel 7 INTERNAL JUMPER SETTINGS 8 Input Polarity 8 Input Sensitivity 8 INSTALLATION AND CONNECTIONS 9 Mounting 9 Temperature Humidity Considerations 9 AC P...

Страница 4: ...nnel into 4 ohm stereo loads 20 Hz to 20 kHz with less than 0 5 THD N 500W per channel into 2 ohm loads 1 kHz with less than 0 5 THD N 700W bridged mono into 8 ohms 20 Hz to 20 kHz with less than 0 5...

Страница 5: ...8 ohm loads Frequency Response 20 20kHz 0dB 1dB Signal to Noise 100dB A Weighted referenced to 4 ohm rated power 22kHz BW Crosstalk 70dB 1kHz referenced to rated power 4 ohm CMRR 70dB at 1kHz Slew Rat...

Страница 6: ...the level controls are set to 0dB attenuation no matter what the position of the knobs 4 9 LEVEL CONTROLS Sets the amount of signal attenuation down to a maximum of 100dB 6 SIGNAL LEVEL AND DIAGNOSTIC...

Страница 7: ...le channel with twice the power The output is provided across the CH 2 red post and the CH 1 black post This output should only be used when the Mono switch is enabled 22 CHANNEL ONE provides the outp...

Страница 8: ...ctor JP103 and JP104 are 6 pin headers that are used to adjust the amplifier s input sensitivity for a wide variety of source levels Each channel can be set to any one of four positions NOTE With no j...

Страница 9: ...to remove shield ground from chassis ground Input sensitivity can be internally configured to any of four industry standard levels see page 7 In stereo mode a separate signal is required for each cha...

Страница 10: ...Above CAUTION To avoid damaging the equipment DO NOT ground any output terminal of the ZR amplifier OUTPUT CONFIGURATION For multi amplifier installations the sequencing feature limits the overall in...

Страница 11: ...e using bridged mono mode ensure that the Input and Output configurations are set correctly 6 Use a voltmeter to determine if the power line voltage is dropping excessively when the amplifier is drive...

Страница 12: ...merchantability and fitness for a particular purpose EXCLUSIONS In no event shall Carver Professional be liable for property damage or any other incidental or consequential damages which may result f...

Отзывы: