background image

13

14

A Phoenix Gold International Company

STANDBY

23

INPUT

CH 2

INPUT

CH 1

GND

LIFT

MONO

GND

LIFT

PUSH

PUSH

25 26 27 28 29 30

24

31

32

33

15 – FUSE CARRIER

Holds the AC mains fuse.

16 – AC MAINS CONNECTOR

IEC type power cord attaches here. 

17 – SEQUENCE CONNECTOR

Used for sequencing power to multiple amps. (See page 11) 

18, 20 &  22 – SPEAKER OUTPUTS

A set of three 4-conductor Neutrik

®

Speakon

®

NL4 connectors to

connect the amplifier to the speakers.

18 - CHANNEL TWO

provides the output of channel two only, on pins 1+/1-.

20 - BRIDGED MONO

uses the output of both channels to create a single channel with

twice the power. The output is provided on both pins 1+/1- and 2+/2- of the Speakon

®

,

allowing the use of all four conductors to lower the cable resistance. This output should only
be used when the Mono switch is enabled.

22 - CHANNEL ONE

actually provides output for channel one AND channel two using a

single 4-conductor cable.
Channel one output is present on pins 1+/1- of the Speakon

®

, and channel two output is

present on pins 2+/2-.

19 & 21 - SPEAKER OUTPUTS

Two pairs of five-way binding posts to connect the amplifier to the
speakers.

19 - CHANNEL TWO

provides the output of channel two across the red(+) post and the

black(-) post.

19 & 21 - BRIDGED MONO

uses the output of both channels to create a single channel with

twice the power. The output is provided across the CH 2 red(+) post and the CH 1 black(-)
post. This output should only be used when the Mono switch is enabled.

22 - CHANNEL ONE

provides the output of channel two across the red(+) post and the

black(-) post

23 & 32 – BALANCED AUDIO INPUTS

Neutrik

®

Combo connectors which accept male XLR, TS and TRS 1/4´´

phone plugs. By default, XLR pin 2 is hot and Tip is hot.  Polarity of the
XLR can be reversed with jumper settings inside the amp. (See page 9)

24 & 31 - BALANCED AUDIO INPUTS

Euro-type connectors used for balanced or unbalanced signals.

25 & 30 – GROUND LIFT SWITCHES

Switches for each channel that disconnect Ground pin of the input
connectors from chassis ground. Used to eliminate ground loop
conditions that cause hum.

26 &  29 – GROUND LIFT STATUS LEDS

These are separate indicators for each channel which light up when the
Ground Lift switches are enabled. 

27 – MONO SWITCH

When the switch is ‘in’, the amp is set to Mono mode. Mono operation
causes the signal connected to the channel Two input to drive both
channels. The channel One input is disabled in Mono mode.

28 – MONO STATUS LED

This indicator will light when the Mono switch is engaged.

33 – STANDARD INPUT MODULE

This replaceable module handles the input signals. Available upgrade
modules include a 4X2 mixer, single/dual zone paging modules, an
expanded mic / line level input module, a computer control and
monitoring module, and a DSP module with EQ, crossover, limiter, and
delay.

7

REAR

Содержание ZR1000

Страница 1: ...USER MANUAL ZR1000 ZR1600 Power Amplifiers...

Страница 2: ...uipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protec...

Страница 3: ...AND STATUS INDICATORS 6 Front Panel 6 Rear Panel 7 INTERNAL JUMPER SETTINGS 8 Input Polarity 8 Input Sensitivity 8 INSTALLATION AND CONNECTIONS 9 Mounting 9 Temperature Humidity Considerations 9 AC P...

Страница 4: ...nnel into 4 ohm stereo loads 20 Hz to 20 kHz with less than 0 5 THD N 500W per channel into 2 ohm loads 1 kHz with less than 0 5 THD N 700W bridged mono into 8 ohms 20 Hz to 20 kHz with less than 0 5...

Страница 5: ...8 ohm loads Frequency Response 20 20kHz 0dB 1dB Signal to Noise 100dB A Weighted referenced to 4 ohm rated power 22kHz BW Crosstalk 70dB 1kHz referenced to rated power 4 ohm CMRR 70dB at 1kHz Slew Rat...

Страница 6: ...the level controls are set to 0dB attenuation no matter what the position of the knobs 4 9 LEVEL CONTROLS Sets the amount of signal attenuation down to a maximum of 100dB 6 SIGNAL LEVEL AND DIAGNOSTIC...

Страница 7: ...le channel with twice the power The output is provided across the CH 2 red post and the CH 1 black post This output should only be used when the Mono switch is enabled 22 CHANNEL ONE provides the outp...

Страница 8: ...ctor JP103 and JP104 are 6 pin headers that are used to adjust the amplifier s input sensitivity for a wide variety of source levels Each channel can be set to any one of four positions NOTE With no j...

Страница 9: ...to remove shield ground from chassis ground Input sensitivity can be internally configured to any of four industry standard levels see page 7 In stereo mode a separate signal is required for each cha...

Страница 10: ...Above CAUTION To avoid damaging the equipment DO NOT ground any output terminal of the ZR amplifier OUTPUT CONFIGURATION For multi amplifier installations the sequencing feature limits the overall in...

Страница 11: ...e using bridged mono mode ensure that the Input and Output configurations are set correctly 6 Use a voltmeter to determine if the power line voltage is dropping excessively when the amplifier is drive...

Страница 12: ...merchantability and fitness for a particular purpose EXCLUSIONS In no event shall Carver Professional be liable for property damage or any other incidental or consequential damages which may result f...