T-362
4–6
Cd16 Compressor Motor Hour Meter / Unit Run Time Hour Meter
Cd16 displays the compressor motor hours. The user can view unit run time by pressing the ENTER key
while in Cd16. Total hours are recorded in increments of 10 hours (i.e., 3000 hours is displayed as 300).
The Compressor Motor Hour Meter display can be reset to 0 by pressing and holding the ENTER key for
5 seconds. The Unit Run Time Hour Meter cannot be reset.
Cd17 Relative Humidity (%)
Cd17 displays the Humidity Sensor (HS) relative humidity reading, as a percent value.
Cd18 Software Revision Number
Cd18 displays the software revision number.
Cd19 Battery Check
Cd19 checks the Controller / DataCORDER battery pack. While the test is running, “btest” will flash on
the right display, followed by the result. “PASS” will be displayed for battery voltages greater than 7.0 volts.
“FAIL” will be displayed for battery voltages between 4.5 and 7.0 volts, and “-----” will be displayed for
battery voltages less than 4.5 volts.
After the result is displayed for four seconds, “btest” will again be displayed, and the user may continue
to scroll through the various codes.
Cd20 Config / Model Number
Cd20 indicates the dash number of the model for which the Controller is configured (i.e., if the unit is a
69NT40-561-253, the display will show “61253”). To display controller configuration database information,
press ENTER. Values in “CFYYMMDD” format are displayed if the controller was configured with a
configuration card or with a valid OEM serial port configuration update; YYMMDD represents the
publication date of the model configuration database.
Cd21 Capacity Mode
Cd21 displays the mode of operation as Unloaded, Standard, or Economized.
Cd22 Compressor State
Cd22 displays the status of the compressor as OFF or On.
Cd23 Evaporator Fan State
Cd23 displays the current state of the evaporator fan as OFF, LOW or HIGH.
Cd25 Compressor Run Time Remaining Until Defrost
Cd25 displays the time remaining until the unit goes into defrost (in tenths of an hour). This value is based
on the actual accumulated compressor running time.
Cd26 Defrost Temperature Sensor Reading
Cd26 displays the Defrost Temperature Sensor (DTS) reading.
Configurable Functions
- Cd27 through Cd37 are user-selectable functions. The operator can change the value
of these functions to meet the operational needs of the container.
Table 4–4 Controller Function Codes
Code Description
Содержание PrimeLINE 69NT40-561-200
Страница 12: ......
Страница 18: ......
Страница 100: ......
Страница 182: ......
Страница 183: ...8 1 T 362 SECTION 8 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 1 LEGEND Standard Unit Configuration ...
Страница 184: ...T 362 8 2 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 2 Schematic Diagram ...
Страница 185: ...8 3 T 362 ELECTRICAL WIRING SCHEMATIC AND DIAGRAMS Figure 8 3 Unit Wiring Diagram Sheet 1 of 2 ...