49
Model PH61
Operating Procedures
Step 5
Using the black brush, clean the drive hub opening
in the rear wall of the mix hopper. (See Figure 83.)
Figure 83
Step 6
Using the double end brush, brush clean the syrup
line fittings.
Step 7
Prepare a sink with an approved 100 PPM sanitizing
solution (examples: Kay-5® or Stera-Sheen®)
.
USE WARM WATER AND FOLLOW THE
MANUFACTURER'S SPECIFICATIONS.
Step 8
Repeat step 3 with the sanitizing solution.
Step 9
Sanitize all parts in the sanitizing solution for a
minimum of 1 minute.
Step 10
Place disassembled parts on clean and sanitized
parts trays.
Step 11
Wipe all exterior surfaces of the freezer with a clean,
sanitized towel.
Sanitizing the Syrup Systems
Two main objectives in your closing procedures
must be to:
1.
Discard all syrup
at least once a week
.
2.
Flush the syrup lines
at least twice a week
.
This must be done on a regular basis
a.
to keep a build-up of old syrup from
clogging the lines, and
b.
to break the bacteria chain which develops
in the tanks and lines.
Remember:
Calibrating the syrup flow must be
done once every morning, especially after flushing
the syrup lines.
Step 1
Sanitizing the syrup tanks.
Pull back on the collar
of the quick disconnect fitting of the air line. Allow
the air pressure to dissipate from the syrup tank.
Disconnect the syrup line.
Remove the syrup tank from its compartment.
Remove the syrup tank lid by lifting up on the locking
lever, and discard the remaining syrup.
Rinse the syrup tank with clean, warm water.
Prepare 1/2 gallon (1.9 liters) of the recommended
sanitizing solution with
warm
water in the syrup
tank. Brush clean the inside and outside of the tank.
Remove the syrup line fitting. Remove the dip tube
and o-ring from the syrup tank.
Thoroughly brush clean the dip tube, syrup line
fitting, and o-ring using the sanitizing solution.
Reassemble the dip tube, o-ring, and syrup line
fitting.
Pour off all the sanitizing solution and place the tank
in an upside-down position on a clean, dry surface to
air dry.
Repeat this procedure for all the syrup tanks.
Step 2
Sanitizing the syrup lines.
Prepare one gallon (3.8
liters) of the recommended sanitizing solution with
warm
water in the spare syrup tank. Replace and
lock the tank lid in position. Place this tank in the
syrup compartment.
Connect one of the air lines and the corresponding
syrup line to the syrup tank filled with sanitizing
solution.
Содержание PH61
Страница 1: ...Model PH61 Heat Treatment Shake Freezer Operating Instructions 048119 M 7 31 07 ...
Страница 12: ...8 Model PH61 Operator Parts Identification Section 4 Operator Parts Identification PH61 Exploded View Figure 1 ...
Страница 14: ...10 Model PH61 Operator Parts Identification 091216 Beater and Door Assembly Figure 2 ...
Страница 77: ...PH61 044816 33 8 07 ...
Страница 78: ...PH61 044816 62 8 07 ...