INSTALLATION
Installation precautions for the wired remote controller:
S
Do not install in a location near heavy oil, vapor or sulfurated gas otherwise this product
will deform which will lead to a system malfunction.
S
Do not install the unit in a location near flammable gas leaks. Once flammable gases leak
and are left near the wired controller, a fire may occur. Do not operate with wet hands. Do
not allow water to enter the wired controller otherwise an electric shock may occur.
S
The wiring should conform to the wired controller current otherwise electric leakage or
heating may occur which may result in fire. Use the correct cables for wiring. No external
force may be applied to the terminal otherwise wire cuts and heating may occur and result
in a fire.
S
This manual contains the installation method for the wired controller. Refer to the wiring
diagram in this manual to connect the wired controller to the indoor unit.
S
The wired controller operates in a low voltage loop circuit. Do not connect the 208
−
230V
power directly to the thermostat. Do not wire this type of wire in the same loop. The wiring
clearance between the configured tubes should maintain a range of 12
−
20 inches (305
−
508mm) or more.
S
The wired controller shielded wire must be well grounded.
S
The wired controller connective cable should not be longer than 66 feet (20 meters).
This manual provides a detailed description of the precautions that should be taken during operation.