5.4.1.
Hydronic Heat Application
The Infinity Touch Control supports 2 types of Hydronic Heat applications:
1. Hot water coil in combination with an FE fan coil and heat pump, or hot
water coil as sole heat source with an FE fan coil.
2. Non--zoned FE fan coil combined with radiant hot water heat.
In either application, a Hydronic Heat kit should be installed in place of an electric
heater. See FE fan coil Product Data for accessory part number. The system will
self--identify that hydronic heat has been installed during electric heater selection.
The system will treat the hot water coil as either auxiliary heat in a heat pump
application, or the sole heat source. Setup options for Hydronic Heat applications
are described in the setup section of this instruction.