WARNING:
The following steps will expose hazardous live parts. Disconnect power between checks
and proceed carefully.
1. Replace any blown fuses and reset any tripped breakers.
2. Repair or replace any loose wires or bad connections.
3. Inspect AFS for proper location and operation.
1. Check that the access door is not open or ajar.
2. Repair or replace any loose wires or bad connections.
3. Replace defective momentary contact switch.
4. Inspect AFS for proper location and operation.
1. Ensure that ON/OFF switch is turned ON.
2. Repair or replace any loose wires or bad connections.
3. Replace defective ON/OFF switch.
4. Inspect AFS for proper location and operation.
1. Remove any objects between adjacent collector plates.
2. Replace corroded or carbonized insulators.
3. Replace any broken ionizing wires.
4. Wash dirty cells..
1. Replace contact board if contacts are corroded and carbonized.
2. Replace any defective wires.
3. With alcohol, clean dirt build-up on contacts and let dry thoroughly.
1. Repair or replace any loose wires or bad connections.
1. Replace defective high frequency power supply.
1. Replace power supply.
2. Replace transformer.
1. Wash dirty cell, including any powder build-up on ionizing wires.
2. Straighten any bent plates.
3. Replace any broken or loose ionizing wires.
1. Ensure good contact between cell and contact boards.
Replace defective contact boards..
Repeat these
steps until all
problems are
eliminated
Содержание EACA 0014