![Carrier Deluxe 38YZA Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/carrier/deluxe-38yza/deluxe-38yza_product-data_2563536030.webp)
30
Multipliers for Determining the Performance With Other Indoor Sections.
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated’’ values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB CFM
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW†
38YZA060-31, 32 Outdoor Section With FX4(A,B)NB060 Indoor Section
65
1750 26.3 24.2 4.04 32.5 29.9 4.19 38.7 35.3 4.33 45.2 40.1 4.46 52.9 48.1 4.63 61.7 61.7 4.83 72.3 72.3 5.11 84.4 84.4 5.41
2000 26.8 24.7 4.10 33.0 30.3 4.23 39.2 35.7 4.35 45.8 40.6 4.46 53.5 48.7 4.61 62.6 62.6 4.80 73.4 73.4 5.06 84.1 84.1 5.27
2250 27.3 25.1 4.17 33.5 30.8 4.29 39.6 36.1 4.39 46.3 41.1 4.49 54.2 49.3 4.62 63.3 63.3 4.80 74.4 74.4 5.02 84.0 84.0 5.20
70
1750 25.3 23.3 4.20 31.8 29.2 4.38 38.3 34.9 4.55 44.7 39.7 4.69 52.2 47.5 4.86 60.9 60.9 5.08 71.3 71.3 5.37 83.2 83.2 5.68
2000 25.9 23.8 4.26 32.4 29.8 4.43 38.8 35.4 4.57 45.3 40.2 4.69 52.9 48.2 4.84 61.7 61.7 5.04 72.4 72.4 5.30 84.3 84.3 5.57
2250 26.4 24.3 4.34 32.9 30.2 4.48 39.3 35.8 4.61 45.8 40.7 4.71 53.5 48.7 4.85 62.4 62.4 5.03 73.2 73.2 5.28 84.1 84.1 5.49
75
1750 24.2 22.3 4.34 31.0 28.5 4.58 37.8 34.4 4.77 44.3 39.3 4.94 51.7 47.0 5.12 60.1 60.1 5.34 70.3 70.3 5.63 82.2 82.2 5.98
2000 24.8 22.8 4.41 31.6 29.1 4.62 38.3 35.0 4.79 44.8 39.8 4.93 52.3 47.6 5.09 60.9 60.9 5.29 71.3 71.3 5.56 83.1 83.1 5.84
2250 25.4 23.3 4.49 32.2 29.6 4.68 38.9 35.4 4.83 45.3 40.3 4.95 52.9 48.1 5.09 61.7 61.7 5.28 72.2 72.2 5.53 83.5 83.5 5.77
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
CC5A/CD5AW
060
0.97
1.08
40FK(A,B)/FK4(C,D)NB
006
0.99
0.99
CK5A/CK5BX
060
0.98
1.04
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
FB4(A,B)NB
070
1.00
1.03
CD5PX
060
0.98
1.00
FC4(B,C)NB
070
1.00
1.03
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
FV4(A,B)NB
006
1.00
1.00
CC5A/CD5AW
060
0.98
1.06
FX4(A,B)NB
060
1.00
1.03
—
—
—
Heat pump heating performance continued