Multipliers for Determining the Performance With Other Indoor Sections.
See notes on pg. 30.
INDOOR
AIR
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
–3
7
17
27
37
47
57
67
EDB CFM
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Capacity
(MBtuh)
Total
Pow-
er
Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW† Total Int*
kW†
38YZA042-31, 32 Outdoor Section With FX4(A,B)NF042 Indoor Section
65
1225 18.7 17.2 2.86 22.6 20.8 2.96 26.5 24.2 3.05 30.8 27.4 3.15 35.8 32.6 3.27 41.5 41.5 3.44 48.2 48.2 3.66 55.3 55.3 3.89
1400 19.0 17.5 2.90 22.9 21.1 2.98 26.9 24.5 3.06 31.2 27.7 3.14 36.3 33.0 3.25 42.1 42.1 3.40 49.0 49.0 3.61 55.5 55.5 3.78
1575 19.3 17.8 2.94 23.2 21.3 3.02 27.2 24.8 3.08 31.6 28.0 3.16 36.7 33.4 3.26 42.6 42.6 3.39 49.5 49.5 3.60 55.7 55.7 3.74
70
1225 18.2 16.7 3.00 22.3 20.5 3.11 26.3 23.9 3.21 30.4 27.0 3.32 35.3 32.2 3.45 40.9 40.9 3.62 47.5 47.5 3.85 54.7 54.7 4.11
1400 18.6 17.1 3.04 22.6 20.8 3.13 26.6 24.3 3.22 30.8 27.4 3.31 35.8 32.6 3.43 41.5 41.5 3.58 48.2 48.2 3.79 55.3 55.3 4.02
1575 18.9 17.4 3.08 23.0 21.1 3.17 26.9 24.5 3.24 31.2 27.7 3.32 36.2 33.0 3.43 42.0 42.0 3.57 48.8 48.8 3.78 55.1 55.1 3.93
75
1225 17.7 16.3 3.14 21.9 20.1 3.26 26.0 23.7 3.38 30.1 26.7 3.49 34.9 31.7 3.63 40.4 40.4 3.81 46.8 46.8 4.05 54.3 54.3 4.38
1400 18.0 16.6 3.18 22.2 20.4 3.28 26.3 24.0 3.39 30.5 27.1 3.48 35.3 32.2 3.61 40.9 40.9 3.76 47.5 47.5 3.99 54.6 54.6 4.23
1575 18.4 16.9 3.22 22.6 20.7 3.32 26.6 24.3 3.41 30.8 27.4 3.49 35.8 32.5 3.60 41.4 41.4 3.75 48.1 48.1 3.96 54.8 54.8 4.15
Indoor
Section
Size
Heating
Indoor
Section
Size
Heating
Capacity
Power
Capacity
Power
CC5A/CD5AC
048
0.98
1.08
CK5A/CK5BA
048
1.00
0.98
CC5A/CD5AW
048
1.00
1.02
CK5A/CK5BT
048
1.00
0.98
CD5AA
048
1.00
1.02
CK5A/CK5BW
048
1.00
0.98
CE3AA
048
1.02
1.04
CK5PA
048
1.00
0.98
CK3BA
048
1.02
1.03
CK5PT
048
1.01
0.99
CK5A/CK5BA
048
1.02
1.03
CK5PW
048
1.00
0.98
CK5A/CK5BW
048
1.02
1.03
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
F(A,B)4(A,B)N(F,B,C)
048
1.02
1.03
CC5A/CD5AW
048
1.00
1.01
FC4(B,C)N(F,B)
048
1.02
1.02
CD5AA
048
1.00
1.01
FV4(A,B)NF
003
1.00
1.00
CE3AA
048
1.00
1.00
005
0.99
0.93
CK3BA
048
1.00
0.98
FX4(A,B)NF
042
1.02
1.01
CK5A/CK5BA
048
1.00
0.98
40FK(A,B)/
FK4(C,D)NF
003
0.99
1.00
CK5A/CK5BT
048
1.00
0.98
005
0.99
0.93
CK5A/CK5BW
048
1.00
0.98
COILS + 58CV(A,X)090-16 VARIABLE SPEED FURNACE
CK5PA
048
1.00
0.98
CE3AA
048
1.01
1.02
CK5PT
048
1.00
0.98
CK3BA
048
1.01
1.00
CK5PW
048
1.00
0.98
CK5A/CK5BA
048
1.01
1.00
COILS + 58MVP040-14 VARIABLE SPEED FURNACE
CK5A/CK5BT
048
1.01
1.00
CC5A/CD5AW
048
1.00
1.01
CK5PA
048
1.01
1.00
CK5A/CK5BW
048
1.00
1.01
CK5PT
048
1.01
1.00
COILS + 58MVP080-14 VARIABLE SPEED FURNACE
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
CD5AA
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.01
CK3BA
048
1.00
1.01
CD5AA
048
1.00
1.01
CK5A/CK5BA
048
1.00
1.01
CE3AA
048
1.00
1.00
COILS + 58MVP080-20 VARIABLE SPEED FURNACE
CK3BA
048
1.00
0.98
CD5AA
048
1.00
1.01
CK5A/CK5BA
048
1.00
0.98
CK3BA
048
1.00
1.01
CK5A/CK5BT
048
1.00
0.98
CK5A/CK5BA
048
1.00
1.01
CK5A/CK5BW
048
1.00
0.98
COILS + 58MVP100-20 VARIABLE SPEED FURNACE
CK5PA
048
1.00
0.98
CD5AA
048
1.00
1.00
CK5PT
048
1.00
0.98
CK3BA
048
1.00
1.00
CK5PW
048
1.00
0.98
CK5A/CK5BA
048
1.00
1.00
COILS + 58CV(A,X)135-22 VARIABLE SPEED FURNACE
CK5A/CK5BW
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.01
COILS + 58MVP120-20 VARIABLE SPEED FURNACE
CD5AA
048
1.00
1.01
CC5A/CD5AW
048
1.00
1.00
CE3AA
048
1.00
1.00
CK5A/CK5BW
048
1.00
1.00
CK3BA
048
1.00
0.98
—
—
—
Heat pump heating performance continued