Detailed cooling capacities* continued
Multipliers for Determining the Performance With Other Indoor Sections
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kw) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kw) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C).
** System kw is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
EWB—Entering Wet Bulb
EVAPORATOR
AIR
CONDENSER ENTERING AIR TEMPERATURES °F
75
85
95
105
115
125
CFM
EWB
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Capacity
MBtuh†
Total
System
kW**
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
Total
Sens‡
38YZA060-31, 32 Outdoor Section With FX4(A,B)NB060 Indoor Section
1750
72
69.2
34.7
4.68
66.0
33.5
5.17
63.2
32.5
5.74
60.2
31.4
6.37
56.5
30.1
7.04
52.3
28.6
7.77
67
64.9
45.1
4.63
61.9
43.9
5.13
58.8
42.6
5.68
55.7
41.4
6.29
52.2
40.0
6.95
48.4
38.5
7.68
63††
61.1
44.2
4.60
58.0
42.8
5.08
55.5
41.7
5.65
52.5
40.4
6.26
49.3
39.0
6.93
45.6
37.4
7.66
62
60.3
55.1
4.59
57.3
53.6
5.07
54.6
52.3
5.62
51.7
50.8
6.23
48.8
48.8
6.90
45.8
45.8
7.64
57
58.7
58.7
4.57
56.2
56.2
5.06
54.0
54.0
5.61
51.5
51.5
6.23
48.9
48.9
6.91
45.9
45.9
7.65
2000
72
69.9
36.1
4.79
66.5
34.9
5.29
63.6
33.9
5.85
60.5
32.8
6.48
56.6
31.4
7.14
52.3
29.9
7.87
67
65.6
47.8
4.75
62.5
46.6
5.24
59.4
45.3
5.79
56.0
44.0
6.40
52.4
42.6
7.06
49.1
41.3
7.82
63††
61.8
46.7
4.71
59.0
45.4
5.20
56.0
44.1
5.75
52.9
42.8
6.36
49.5
41.4
7.03
45.8
39.7
7.76
62
61.3
58.8
4.70
58.2
57.1
5.19
55.9
55.7
5.76
53.2
53.2
6.37
50.4
50.4
7.06
47.3
47.3
7.80
57
60.6
60.6
4.70
57.9
57.9
5.18
55.5
55.5
5.74
52.9
52.9
6.35
50.1
50.1
7.03
46.9
46.9
7.77
2250
72
70.3
37.4
4.90
67.3
36.4
5.41
63.8
35.1
5.96
60.6
34.1
6.58
56.6
32.6
7.24
52.2
31.1
7.96
67
66.0
50.3
4.86
62.9
49.1
5.35
59.7
47.8
5.90
56.2
46.4
6.50
53.2
45.2
7.19
49.7
43.8
7.96
63††
62.3
49.0
4.82
59.8
47.9
5.33
56.3
46.4
5.86
53.1
45.1
6.47
49.7
43.5
7.13
45.8
41.9
7.86
62
62.2
61.8
4.82
59.2
59.2
5.30
57.0
57.0
5.87
54.3
54.3
6.49
51.3
51.3
7.17
48.5
48.5
7.95
57
62.1
62.1
4.82
59.3
59.3
5.31
56.7
56.7
5.86
54.0
54.0
6.47
51.0
51.0
7.15
48.2
48.2
7.92
Indoor
Section
Size
Cooling
Indoor
Section
Size
Cooling
Capacity
Power
Capacity
Power
CC5A/CD5AW
060
0.97
1.02
40FKA/FK4CNB
006
1.01
1.00
CK5A/CK5BX
060
0.98
1.02
COILS + 58CV(A,X)110-22 VARIABLE SPEED FURNACE
FB4(A,B)NB
070
0.99
1.04
CD5PX
060
0.97
1.00
FC4(B,C)NB
070
0.99
1.04
COILS + 58CV(A,X)155-22 VARIABLE SPEED FURNACE
FV4(A,B)NB
006
1.00
1.00
CC5A/CD5AW
060
0.97
0.98
FX4(A,B)NB
060
0.99
1.04
—
—
—