14
Fig. 12 - Typical Aquazone Deluxe D control wiring (three-phase unit)
Legend
AL
Alarm relay contacts
BM
Blower motor
BMC
Blower motor capacitor
BR
Blower relay
CAP
Compressor capacitor
CB
Circuit breaker
CO
Sensor, condensate overflow
FP1
Sensor, water coil freeze protection
FP2
Sensor, air coil freeze protection
GND
Ground
HP
High pressure switch
HWTS
High (leaving) water temperature switch
JW
Clippable field selection jumper
LOC
Loss of charge pressure switch
MV
Motorised valve
P1
Field wiring terminal block
PB
Power block
PM
Performance Monitor
PSC
Permanent split capacitor
RVS
Reversing valve solenoid
TRANS
Transformer optional wiring
Field line voltage wiring
Field low voltage wiring
Printed circuit trace
Optional wiring
Relay/contactor coil
Thermistor
Condensate pan
Circuit breaker
LED
Capacitor
Solenoid coil
Relay contacts - NO
Temperature switch
Switch - loss of charge
Ground
Wire nut
* Optional wiring
Notes:
1.
Compressor thermally protected internally.
2.
All wiring to the unit must comply with local codes.
3.
Neutral of 380/415-3-50 is required. Transformer is wired to 240 V (ORG) lead
for 415-3-50. For 380-3-50 switch ORG and (RED) leads at PB(2) and insulate
ORG lead. Transformer uses separate circuit breaker.
4.
FP1 thermistor provides freeze protection for water. When using anti-freeze
solutions, cut JW3 jumper.
5.
Check installation wiring inforation for specific thermostat hook-up. Refer to
thermostat installation instructions for wiring to the unit. Thermostat wiring must
be ‘Class 1’ and voltage rating equal to or greater than unit supply voltage.
6.
24-V alarm signal shown. For dry alarm contact, cut JW4 jumper, and dry
contact will be available between AL1 and AL2.
7.
Transformer secondary ground via microprocessor board stand-offs and
screws to control box. (Ground available from top two stand-offs as shown.)
8.
Blower motor is factory-wired for medium and high speeds. For any other
combination of speeds, at the motor attach black wire to the higher of the two
desired speed taps, and the blue wire to the lower of the two desired speed
taps.
9.
Blower motor is factory-wired for high and low speeds. No other combination of
speeds is available.
E
L3
L2
L1
CB
YEL
24V
RED
(220V)
BLK
BLK
G/Y
BLK
BLK
BLK
BLK
ORG
(240V)
YEL OR
WHT
BRN
YEL
BLK
BLK
BLK
BLK
L3
L2
L1
T3
T2
T1
CC
CC
G/Y
G/Y
BLK
BLU
RED
BM
H
M
L
6
7
8
BR2
T3
T2
T1
6
5
4
3
2
1
BMC
LUG
T3
T2
T1
CC
PB
BR1
BR2
TRANS
Y
O
G
R
C
XI
Y1
O/W2
G
R
C
AL1
W1
AL2
A
P3
R
C
JW1
LP
G
1
2
3
4
5
6
7
8
9
10
12
HP
LOC
FP1
RV
CO
P7
P6
CCG
24V
DC
EH1
EH2
RED
BLU
BRN
GRY
GRY
HP
LOC
FP1
FP2
BRN
BRN
ORG
YEL
VIO
VIO
VIO
TXV
NSB
ESD
OVR
H
P2
C
R
Y2
P1
R
R
COM
NC2
NO2
COM
NC1
NO1
ACC1
ACC2
JW2
FP2
JW3
FP1
N.O.
FP2
CC
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
CO
VIO
YEL
CC
A2
A1
Y
R
RED
BLK*
HWTS
BLK*
GRY
BR2
BR1
BRN
BRN
1
0
COM
NO
NC
COM
NO
COM2 COM1
R C S
C
S
6
8
YEL
BR1
COMPR
RELAY
GRY
YEL
BLU
RED
RED
JW4
AL2
DRY
PB
Earth (GRD)
N (Neutral)
Power supply
Refer to data plate
Use copper
conductors only
Component location
Lug
Compr.
See note 8
Typical heat
pump T-stat
Compr.
Cooling
Fan
24 V a.c.
Common
Alarm
See note 6 for
dry alarm contact
See note 7
Alarm
relay
See
note 6
See note 5
Ground lug
Test
pins
See
note 4
Low temp.
Low temp.
Relay
Off On
Relay
PM: Disable/enable
Unit stage: 2/1
T-stat: heat cool/heat pump
RV on 8/RV on 0
Dehumid/normal
Not used
Boilerless: Enable/disable
Boilerless: 4.4
°
C/10
°
C
Dry
Dip switch package
Dip switch package
Off
On
DXM
Microprocessor
control logic
See note 7
Fan enable
relay
Fan
speed
relay
Status
Test
Fault
See note 4
TXV units
Cap. tube
units
RV relay
Compr.
relay
Acc1
Functions
Acc2
Functions
H:Hi fan/dehumid
Not used
G
S1
S2