26
10 - OPTIONS AND ACCESSORIES
Options
No. Description
Advantages
Use for
61XWH range
Star / delta start
25A Star / Delta start on each compressor
Reduced start-up current
3-5, 10
Master/slave operation 58
Unit equipped with supplementary water outlet
temperature sensor kit to be field-installed allowing
master/slave operation of two units connected in
parallel
Optimised operation of two units connected in
parrallele operation with operating time equalisation
3-17
Single power
connection point
81 Unit power connection via one main supply connection Quick and easy installation
61XWHLZE /
61XWH-ZE
10-17,
61XWHHZE 10
No disconnect switch 82A Unit without disconnect switch, but with short-circuit
protection device
Permits an external electrical disconnect system
for the unit (field-supplied), while ensuring unit
short circuit protection
3-17
Evap. single pump
power/control circuit
84 Unit equipped with an electrical power and control
circuit for one pump evaporator side
Quick and easy installation: the control of fixed
speed pumps is embedded in the unit control
3-10 Not
available for
61XWHHZE
Evap. dual pumps
power/control circuit
84D Unit equipped with an electrical power and control
circuit for two pumps evaporator side
Quick and easy installation: the control of fixed
speed pumps is embedded in the unit control
3-10 Not
available for
61XWHHZE
Cond. single pump
power/control circuit
84R Unit equipped with an electrical power and control
circuit for one pump condenser side
Quick and easy installation: the control of fixed
speed pumps is embedded in the unit control
3-10 Not
available for
61XWHHZE
Evaporator with one
pass more
100A Evaporator with one pass more on the water side
Optimise chiller operation when the chilled water
circuit is designed with low waterflows (high delta
T evaporator inlet/oulet)
3-17
Evaporator with one
pass less
100C Evaporator with one pass on the water side.
Evaporator inlet and outlet on opposite sides.
Easy to install, depending on site. Reduced
pressure drops
3-17
Condenser with one
pass more
102A Condenser with three passes on the water side.
Condenser inlet and outlet on opposite sides.
Adapted to sites where larger temperature
differences and smaller water flow rates are
required
3-17
Condenser with one
pass less
102C Condenser with one pass on the water side.
Condenser inlet and outlet on opposite sides.
Easy to install, depending on site. Reduced
pressure drops
3-17
21 bar evaporator
104
Reinforced evaporator for extension of the maximum
water-side service pressure to 21 bar (standard 10
bar)
Covers applications with a high water column
evaporator side (typically high buildings)
3-17
21 bar condenser
104A
Reinforced condenser for extension of the maximum
water-side service pressure to 21 bar (standard 10
bar)
Covers applications with a high water column
condenser side (typically high buildings)
3-17
Reversed evaporator
water connections
107 Evaporator with reversed water inlet/outlet
Easy installation on sites with specific requirements
3-17
Reversed condenser
water connections
107A Condenser with reversed water inlet/outlet
Easy installation on sites with specific requirements
3-17
J-Bus gateway
148B Two-directional communication board complying with
JBus protocol
Connects the unit by communication bus to a
building management system
3-17
Lon gateway
148D Two-directional communication board complying with
Lon Talk protocol
Connects the unit by communication bus to a
building management system
3-17
Bacnet over IP
149 Two-directional high-speed communication using
BACnet protocol over Ethernet network (IP)
Easy and high-speed connection by ethernet line
to a building management system. Allows access
to multiple unit parameters
3-17
Control for low cond.
temperature
152 Output signal (0-10 V) to control the condenser water
inlet valve
Simple installation: for applications with cold water
at condenser inlet (ex. ground-source, groundwater-
source, superficial water-source applications) the
signal permits to control a 2 or 3-way valve to
maintain condenser water temperature (and so
condensing pressure) at acceptable values
3-17
Energy Management
Module
156 EMM Control board with additional inputs/outputs.
See Energy Management Module option chapter
Extended remote control capabilities (Set-point
reset, ice storage end, demand limits, boiler on/off
command...)
3-17
Compliance with Swiss
regulations
197
Additional tests on the water heat exchangers: supply
(additional of PED documents) supplementary
certificates and test certifications
Conformance with Swiss regulations
3-17
Low noise level
257 Evaporator sound insulation
3 dB(A) quiter than standard unit
5-17
Welded evaporator
connection kit
266
Victaulic piping connections with welded joints
Easy installation
3-17
Welded condenser
water connection kit
267
Victaulic piping connections with welded joints
Easy installation
3-17
Flanged evaporator
water connection kit
268
Victaulic piping connections with flanged joints
Easy installation
3-17
Flanged condenser
water connection kit
269
Victaulic piping connections with flanged joints
Easy installation
3-17
Conformance with
Moroccan regulations 327
Specific regulatory documentation
Conformance with Moroccan regulations
3-17