18
Table 2 — Physical Data — 62X, B-BXL Cabinet
UNIT 62X B CABINET
03
04
05
06
07
08
10
12
15
18
20
NOMINAL CAPACITY (TONS)
3
4
5
6
7
8
10
12
15
17.5
20
COMPRESSOR
Unit without ERV
Quantity/Unit … Model
1...ZPD34
1...ZPD42
1...ZPD51
1...ZPD54
1...ZPD72
1...ZPD83
1...ZPD51,
1...ZP51
or
2...ZPD51
1...ZPD61,
1...ZP61
or
2...ZPD61
1...ZPD72,
1...ZP72 or
2...ZPD72
1...ZPD91,
1...ZP91
or
2...ZPD91
1...ZPD103,
1...ZPD103
or
2...ZPD103
Unit with ERV
Quantity/Unit … Model
1...ZPD34
1...ZPD42
1...ZPD51
1...ZPD61
1...ZPD72
1...ZPD83
1...ZPD51,
1...ZP51
or
2...ZPD51
1...ZPD61,
1...ZP61
or
2...ZPD61
1...ZPD83,
1...ZP83 or
2...ZPD83
1...ZPD91,
1...ZP91
or
2...ZPD91
1...ZPD103,
1...ZPD103
or
2...ZPD103
Number of Refrigerant Circuits
1
2
Oil
Pre-Charged
REFRIGERANT TYPE
R-410A
CONDENSER COIL
Minimum Capacity Face Area (sq ft)
10.0
10.0
10.0
13.5
13.5
13.5
27
27
27
27
40
High Capacity Face Area (sq ft)
—
—
—
—
27.0
27.0
—
—
40
40
54
CONDENSER FAN
Minimum Capacity
Nominal Cfm (total)
4000
4000
4000
5200
5200
5200
11200
11200
10600
10600
15600
Quantity … Diameter (mm)
1...630
1...630
1...630
1...630
1...630
1...630
2...630
2...630
2...630
2...630
3...630
Motor Hp
1.3
High Capacity
Nominal Cfm (total)
—
—
—
—
11200
11200
—
—
15600
15600
20800
Quantity … Diameter (in.)
—
—
—
—
2...630
2...630
—
—
3...630
3...630
4...630
Motor Hp
—
—
—
—
1.3
1.3
—
—
1.3
1.3
1.3
HIGH-PRESSURE SWITCH (PSIG)
Cutout
640
Reset (Manual)
595
EVAPORATOR COIL
Face Area without ERV (sq ft)
2.8 2.8
2.8
4.7
4.7
4.7
7
7
7
10
10
Face Area with ERV (sq ft)
7
7
7
10
10
10
12
12
Use C Cabinet
SUPPLY FAN
Backward Curved ECM (mm)
355, 450
Airfoil (in.)
12, 14, 16
Backward Inclined (in.)
10, 11, 12, 14, 16
Nominal Cfm 100% OA
450
600
750
900
1050
1200
1500
1800
2250
2700
3000
Motor Hp Range
ECM, 1, 1. 5, 2, 3, 5
OPTIONAL HOT GAS REHEAT AND
LIQUID SUBCOOLING COIL
Face Area without ERV (sq ft)
2.8
2.8
2.8
4.7
4.7
4.7
7
7
7
10
10
Face Area with ERV (sq ft)
7
7
7
10
10
10
12
12
Use C Cabinet
LOW-PRESSURE SWITCH (PSIG)
Cutout
35
Reset (Auto)
55
CONDENSATE DRAIN CONNECTION
(NPT) (in.)
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
0.75
OPTIONAL GAS HEAT SECTION
Gas Input Sizes (Btuh x 1000)
75, 100, 150, 200
Gas Input Sizes (Btuh x 1000) XL
Cabinet
200, 300, 400
Control Type
Stages (no. of stages)
2
Stages XL Cabinet (no. of stages)
4
Modulating (% range)
5:1, 10:1*
Efficiency (Steady State) (%)
80
Supply Line Pressure Range
(in. wg)
5.0 min. - 13.5 max
Rollout Switch Cutout Temp (F)
350
Gas Valve Quantity
1 Std - 2 with modulating option
Manifold Pressure (in. wg)
Natural Gas Std
3.5
LP Gas Special Order
10
OPTIONAL ELECTRIC HEAT
Size Range (kW)
5, 10, 15, 20, 25, 30, 35, 40, 50, 60, 70, 80, 100
Control Type
Stages (no. of stages)
1, 2, 4
SCR (% range)
0-100
OPTIONAL HOT WATER HEAT COIL
WITH ERV
22.5 x 42, 2 row, 10 FPI,
with
1
/
2
in. tubes
30 x 45, 2 row, 10 FPI,
with
1
/
2
in. tubes
33.75 x 44, 2 row, 10
FPI, with
1
/
2
in. tubes
Use C Cabinet
OPTIONAL HOT WATER HEAT COIL
WITHOUT ERV
17.5 x 20, 2 row, 10 FPI,
with
1
/
2
in. tubes
17.5 x 34, 2 row, 10 FPI,
with
1
/
2
in. tubes
22.5 x 42, 2 row, 10 FPI,
with
1
/
2
in. tubes
30 x 45, 2 row, 10 FPI,
with
1
/
2
in. tubes