WIRING DIAGRAM #0962I-5322 | 62XJ04PBJT-JFATACW | 208/230/460/575-3-60 | SHEET 8 OF 8 | 10/31/2017 DWN
LWF
CHK
DS
.
F6
F5
L2
L1
EGL
(SEE FURNACE WIRING DIAGRAM)
G-14
GAS FURNACE LINE
VOLTAGE TERMINALS
GAS FURNACE POWER SUPPLY FOR 230 VOLT UNITS
BK-14
BL-14
GAS FURNACE POWER SUPPLY FOR 208 VOLT UNITS (BUCKBOOST TRANSFORMER)
L2
L1
EGL
(SEE FURNACE WIRING DIAGRAM)
H1
SPLICE
SPLICE
G-14
GAS FURNACE LINE
VOLTAGE TERMINALS
H2
H3
SPLICE
H4
X1
SPLICE
X2
X3
X4
BK-14
T4
F6
F5
BK-14
R-14
F6
F5
BK-14
BL-14
460V
230V
H1
H4
X1
X4
T4
H2
H3
X3
X2
G-14
L2
L1
EGL
(SEE FURNACE WIRING DIAGRAM)
G-14
F8
F7
R-14
Y-14
R-14
GAS FURNACE POWER SUPPLY FOR 460 VOLT UNITS
500 VA
Y-14
Class CC,
600volts,
Time Delay
GAS FURNACE LINE
VOLTAGE TERMINALS
PDB
BK-14
BL-14
2 amps fuse : 500VA
3 amps fuse : 750VA
2 amps fuse : 500VA
3 amps fuse : 750VA
Class CC,
600volts,
Time Delay
BK-14
BL-14
PDB
Y-14
Class CC,
600volts,
Time Delay
4.5 amps fuse : 100VA
8 amps fuse : 250VA
Class CC,
600volts,
Time Delay
3 amps fuse : Single Gas Furnace
6 amps fuse : Dual Gas Furnace
BK-14
BL-14
PDB
RELAY COIL
NORMALLY OPEN CONTACTS
IDENTIFIABLE TERMINAL
NORMALLY CLOSED CONTACTS
HEATER-FACTORY WIRING
EARTH GROUND
CHASSIS (PANEL) GROUND
SYMBOL LEGEND
POWER SUPPLY TERMINAL CONNECTION
Isolaon Relays TERMINAL BOARD
FACTORY WIRING
TIMER RELAY- TR1-090LH15
RHLGP-A:
AUTO RECYCLE HIGH LOW GAS
PRESSURE SWITCH- OPTIONAL
Fenwall 35-61-xxxxx Ignion Control
When high and low gas pressure switch is
furmished, remove this jumper.
Note:1
EGL
T1
240V
1
CLASS 2
50/60 HZ
230 VOLT, 1-PHASE, 60-HERTZ POWER SUPPLY
L2
S1
SRTN
F
L
L
240T6T07 Controller
WHT
BLK
BLK
BLK
L1
N
L1
IND
IGNITION CONTROL
Modulang Furnace Control Panel
WIRE ALL SHIELD WIRES TO CLOSEST TB-A or TB-D
“GND” TERMINAL AT THE CONTROL PANEL
4
COM
T1
T2
T3
T5
T6
T4
T8
T9
T7
24V
HAPS
EST
R1
E Valve
Maxitrol
SC-40
J1
Open
T11 (+)
T12 (-)
YEL
BLU
APS-2
AIR SWITCH-HIGH
3
(+)
(-)
(+)
(-)
24V SIG
EXA
Valve
T2
T1
HR
NO
C
NC
C
High and Low
Gas Pressure
Switches
NC
NO
HIGH GAS
LOW GAS
Note:1
BLU
HI LIMIT
PUR
ROLL OUT
SWITCH NO. 1
ROLL OUT
SWITCH NO. 2
ORG
ORG
PUR
APS-1
AIR SWITCH-LOW
ORG
ORG
T’stat
24V
MV
Alarm
Gnd
V2
Gnd
Syst.
APS
(PSW)
Sense
Spark
FLAME SENSOR
SPARK IGNITER
5
BLU
BLU
BLU
BLU
Series 5 Ignion Control
K
L
B
G
R
O
(Com)
DRAFT INDUCER
BLU
GRY
LO
HI
4
YEL
YEL
BLU
GRY
YEL
YEL
YEL
0-10VDC Analog Input
(Polarity Sensive)
ON
1 2 3 4
WIRE TO
“EGB”
4
W
BK
24VAC Alarm
Indicator
HR
13
14
ISOLATION RELAYS
367
W1
C
W
BL
See unit’s 24v
terminal board
TB1
BCTL
BL
0-10VDC INPUT
Gnd
UO-6
See ALC PAGE