PERFORMANCE AND ELECTRICAL DATA (CONT.)
MODEL 52ME (230/208--1--60)
MODEL
NUMBER
52ME
CAPACITY
EER
COP
VOLTAGE
RANGE
COOLING
Cooling
Heating
AMPS
WATTS
Rev. Cyc.
Electic
U07--- --- ---3
---
---
SEE POWER
CORD
SELECTION
GUIDE
BELOW
---
---
187 --- 253
---
---
U09--- --- ---3
8800 / 9000
---
11.4 / 11.4
---
3.9 / 3.7
770 / 790
U12--- --- ---3
12,000 / 12,100
---
11.4 / 11.5
---
5/ 4.7
1060 / 1070
U15--- --- ---3
---
---
---
---
---
---
MODEL
NUMBER
52ME
POWER
FACTOR
(%)
FAN MOTOR
R---22
CHARGE
(OZ)
DEHUM.
(Pint/Hr)
SENSIBLE
HEAT
FACTOR
APPROX.
CHASSIS
SHIP WT.
(lb)
Indoor
Motor
HP
Indoor
Motor
Full Load
Amps
Indoor CFM
Out-
door
Motor
HP
Outdoor
Motor
Full Load
Amps
Low
Med
High
U07--- --- ---3
---
---
---
---
---
---
---
---
---
---
---
125
U09--- --- ---3
98
0.029
0.2
265
290
330
0.088
0.6
28.9
2.9
0.73
125
U12--- --- ---3
100
0.029
0.2
280
300
320
0.088
0.6
36.0
3.9
0.71
140
U15--- --- ---3
---
---
---
---
---
---
---
---
---
---
---
150
LEGEND
EER —
Energy Efficiency Ratio
*
Rated in accordance with ARI Standard 380-93.
† Fan motor indoor CFM (LO/HI) shown for 230-1-60 units.
POWER CORD SELECTION GUIDE
52M PTACs are not individually equipped with a power cord, so one must be ordered separately
based on the voltage and ampeage of your electrical circuit. If the unit is to be plugged into a
receptacle, then a line cord connection kit needs to be selected. If it will be permanently connnected,
a hardwire connection must be used.
Model No.
Voltage
Receptacle Type
Heating
(BTUH)
Heater
(Kw)
Input Power
Current
(Amps)
Branch Cir-
ciut Full
Amps
PWRCORD---230V---15A
208/230V
15 amp /250
5631 / 6949
2
1650 / 2036
11.3
15
PWRCORD---230V---20A
20 amp /250
8556 /
10393
3
2507/ 3045
17.3
20
PWRCORD---230---30A
30 amp /250
13778 /
16990
5
4037 / 4978
27.1
30
RECEPTACLE AND FUSE TYPES
UNIT NAMEPLATE VOLTAGE
230/208
OUTLET RATED VOLTS/AMPS
250/15
250/20
250/30
OUTLET BLADE CONFIGURATION
RECEPTACLE TYPE
A
B
C
NEMA CONFIGURATION
6--- 15R
6--- 20R
6--- 30R
TIME DEALY FUSE OR HACR CIRCUIT BREAKER (AMPS)
15
20*
30
LEGEND
HACR
---
Heating, Air Conditioning, and Refrigeration
NEMA
---
National Electrical Manufacturers Association
* May be used for 15---amp applications if fused for 15 amps.
New York City Department of Buildings, Material
and Equipment Acceptance — MEA #------ ---- --