32

PERFORMANCE AND ELECTRICAL DATA (CONT.)

MODEL 52ME (230/208--1--60)

MODEL

NUMBER

52ME

CAPACITY

EER

COP

VOLTAGE

RANGE

COOLING

Cooling

Heating

AMPS

WATTS

Rev. Cyc.

Electic

U07--- --- ---3

---

---

SEE POWER

CORD

SELECTION

GUIDE

BELOW

---

---

187 --- 253

---

---

U09--- --- ---3

8800 / 9000

---

11.4 / 11.4

---

3.9 / 3.7

770 / 790

U12--- --- ---3

12,000 / 12,100

---

11.4 / 11.5

---

5/ 4.7

1060 / 1070

U15--- --- ---3

---

---

---

---

---

---

MODEL

NUMBER

52ME

POWER

FACTOR

(%)

FAN MOTOR

R---22

CHARGE

(OZ)

DEHUM.

(Pint/Hr)

SENSIBLE

HEAT

FACTOR

APPROX.

CHASSIS

SHIP WT.

(lb)

Indoor

Motor

HP

Indoor

Motor

Full Load

Amps

Indoor CFM

Out-

door

Motor

HP

Outdoor

Motor

Full Load

Amps

Low

Med

High

U07--- --- ---3

---

---

---

---

---

---

---

---

---

---

---

125

U09--- --- ---3

98

0.029

0.2

265

290

330

0.088

0.6

28.9

2.9

0.73

125

U12--- --- ---3

100

0.029

0.2

280

300

320

0.088

0.6

36.0

3.9

0.71

140

U15--- --- ---3

---

---

---

---

---

---

---

---

---

---

---

150

LEGEND

EER —

Energy Efficiency Ratio

*

Rated in accordance with ARI Standard 380-93.

† Fan motor indoor CFM (LO/HI) shown for 230-1-60 units.

POWER CORD SELECTION GUIDE

52M PTACs are not individually equipped with a power cord, so one must be ordered separately

based on the voltage and ampeage of your electrical circuit. If the unit is to be plugged into a

receptacle, then a line cord connection kit needs to be selected. If it will be permanently connnected,

a hardwire connection must be used.

Model No.

Voltage

Receptacle Type

Heating

(BTUH)

Heater

(Kw)

Input Power

Current

(Amps)

Branch Cir-

ciut Full

Amps

PWRCORD---230V---15A

208/230V

15 amp /250

5631 / 6949

2

1650 / 2036

11.3

15

PWRCORD---230V---20A

20 amp /250

8556 /

10393

3

2507/ 3045

17.3

20

PWRCORD---230---30A

30 amp /250

13778 /

16990

5

4037 / 4978

27.1

30

RECEPTACLE AND FUSE TYPES

UNIT NAMEPLATE VOLTAGE

230/208

OUTLET RATED VOLTS/AMPS

250/15

250/20

250/30

OUTLET BLADE CONFIGURATION

RECEPTACLE TYPE

A

B

C

NEMA CONFIGURATION

6--- 15R

6--- 20R

6--- 30R

TIME DEALY FUSE OR HACR CIRCUIT BREAKER (AMPS)

15

20*

30

LEGEND

HACR

---

Heating, Air Conditioning, and Refrigeration

NEMA

---

National Electrical Manufacturers Association

* May be used for 15---amp applications if fused for 15 amps.

New York City Department of Buildings, Material

and Equipment Acceptance — MEA #------ ---- --

52M

Содержание 52M Performance Series

Страница 1: ...ation 9 Wall Thermostat Interface 9 Energy Management EM Interface 10 Power Cord for 265V Units 10 Power Cord Protection for 230 208V Units 11 Bi Molded Condenser Shroud 11 Easy Access Chassis 11 Enha...

Страница 2: ...ies 52M whisper quiet model is Carrier s quietest and most energy efficient PTAC unit ever The Performance refrigerant system utilizes the highest efficiency compressors and coil design to achieve max...

Страница 3: ...9 000 10 9 8 400 3 5 239 292 275 285 300 3 2 825 125 52MQ U12 4 11 400 10 8 10 600 3 239 292 220 250 290 4 2 1 050 140 52MQ U15 4 15 000 POWER CORD SELECTION 52M PTACs are not individually equipped wi...

Страница 4: ...eat pump models offer substantial savings over models with conventional electric resistance heaters S Individual units allow tenants to choose the degree of comfort and operating economy S Rapid servi...

Страница 5: ...the space down to the desired temperature during very hot days The result could be warm and humid or warm and dry conditioned space Oversizing If a PTAC unit is oversized cooling capacity is greater...

Страница 6: ...l Arm Allows outdoor air into room through vent filter for improved air quality S Control Door Provides protection for controls and enhances appearance S Improved Condensate Removal Minimizes condensa...

Страница 7: ...ts S No bulky duct system S No seasonal changeover QUIET OPERATION Occupants and neighbors are protected against noise intrusion Indoor sound reduction is achieved through the units two fan motor and...

Страница 8: ...l sleeves are available in a variety of sizes for most standard and deep wall applications All metal wall sleeves come with factory installed insulation designed to minimize heat loss and reduce outdo...

Страница 9: ...or but can easily be adjusted to an 80 degree angle to the floor Air discharge upward Air discharge outward Default A07550 Reversible Polycarbonate Discharge Grille DIGITAL KEYPAD AND ELECTRONIC DISPL...

Страница 10: ...The EM interface is standard and provides a simple to install Energy Management connection The unit has a removable terminal connector to make field wiring easy When 24VAC is supplied to the input th...

Страница 11: ...Plug Head BI MOLDED CONDENSER SHROUD The bi molded condenser shroud provides easy access for service and maintenance of the condenser coil and related components BI MOLDED CONDENSER SHROUD A07677 Bi...

Страница 12: ...d coils keeping coils from direct contact with the basepan and providing additional protection against corrosion A07552 CONDENSATE DRAIN VALVE The temperature activated drain valve opens when the outd...

Страница 13: ...ow for both heating and cooling functions and remains energized as long as the controls are in the heat position When the cooling controls are activated the valve automatically reverses to the cooling...

Страница 14: ...s Payback in Months I 06 08 10 34 26 45 68 57 10 21 16 13 43 08 57 44 71 80 21 16 13 58 20 77 60 97 00 19 14 11 68 34 91 12 113 90 19 14 12 II 06 08 10 57 12 76 16 95 20 13 9 8 71 76 95 68 119 60 13 9...

Страница 15: ...DISPLAY WALL THERMOSTAT AND ENERGY MANAGEMENT INTERFACE CONFIGURATION DIP SWITCHES A06752 PRODUCT CATALOG NUMBER Electrical Data 3 230 208 v 60 Hz 4 265 v 60 Hz Cooling Capacity nominal 07 7 000 Btuh...

Страница 16: ...aximum protection and appearance All Carrier s polymer wall sleeves are made from a molded polymer that is designed for strength and durability This material has excellent corrosion resistance and a f...

Страница 17: ...MOLDING For a superior look and to hide any construction imperfections use Carrier s wall sleeve molding kit to trim the wall sleeve to the wall The molding kit is a perfect solution and can be used w...

Страница 18: ...asily from inside the room These elegant grilles available in many standard colors have baked enamel finishes containing 50 Kynarr resin for a superior finish that will withstand the most extreme cond...

Страница 19: ...t be followed since a louver that is restrictive or allows re circulation will result in a reduction of the unit s capacity and efficiency and will ultimately shorten the compressor life X Y X Y X Y X...

Страница 20: ...aximum clearance is 5 1 2 inches IMPORTANT All standard cord connected 265 v PTAC units will require a field installed electrical subbase accessory per UL and NEC electrical codes All subbase models a...

Страница 21: ...ASE FUSE 30A Thefusekit provides in lineovercurrent protectionat the unit when required by NEC National Electric Code or local codes IMPORTANT The Fuse Kit can only be used with the electrical or hard...

Страница 22: ...dels Part No PTACSTAT NP HP A heat pumps This low voltage easy to use non programmable thermostat provides maximum guest comfort A07135 Non Programmable Thermostat Digital Programmable Thermostat Part...

Страница 23: ...in the wafer area A07748 Drain Kit Power Vent with Power Door Kit Part No 52M PWRVENT DOOR Carrier s power vent kit utilizing a specially designed fan when installed in the unit s fresh air vent will...

Страница 24: ...ntractor Installed wall sleeve must be level from side to side and front to back 208 230 v 42 1067 ACCESSORY WALL SLEEVE HINGED CONTROL ACCESS DOOR DISCHARGE GRILLE REMOVABLE FRONT PANEL 2 03 51 6 3 9...

Страница 25: ...7381 Standard and Extended Metal Insulated Wall Sleeve NOTES All Sleeves 1 Never install fasteners through bottom of sleeve 2 Never use rails to level sleeve MAIN STUD JACK STUD CRIPPLE FLOOR SUB FLOO...

Страница 26: ...y have to be notched to accommodate service cord 2 If more than 4 in of sleeve projects into room an accessory subbase must be used for support 3 For walls 2 in thick or less an accessory subbase must...

Страница 27: ...UM CLEARANCE FOR INDOOR AND OUTDOOR DISCHARGE AIR EQUIPMENT OPERATION HAZARD Failure to follow this caution may result in equipment damage or improper operation Blocking indoor or outdoor discharge ai...

Страница 28: ...VIEW ACCESSORY SUBBASE ELECTRICAL CONNECTIONS NOTES 1 Accessory subbase is required for applications where Wall sleeve extends 4 or more inches into the room Wall thickness is less than 2 inches All 2...

Страница 29: ...ox Wire Terminal for Wall Thermostat Models R W Y O Gh Gl C A07073 Terminal Connector Removal and Replacement THERMOSTAT WIRE ROUTING UNDER SLEEVE BEHIND FRONT PANEL A07074 Terminal Wire Routing NOTE...

Страница 30: ...ORD SELECTION GUIDE 52M PTACs are not individually equipped with a power cord so one must be ordered separately based on the voltage and ampeage of your electrical circuit If the unit is to be plugged...

Страница 31: ...o one must be ordered separately based on the voltage and ampeage of your electrical circuit If the unit is to be plugged into a receptacle then a line cord connection kit needs to be selected If it w...

Страница 32: ...equipped with a power cord so one must be ordered separately based on the voltage and ampeage of your electrical circuit If the unit is to be plugged into a receptacle then a line cord connection kit...

Страница 33: ...he voltage and ampeage of your electrical circuit If the unit is to be plugged into a receptacle then a line cord connection kit needs to be selected If it will be permanently connnected a hardwire co...

Страница 34: ...D SUPPLIED LEGEND NOTES 1 To size transformer use the following equation Quantity of PTAC units x 12 va Transformer Size va Example 110 PTAC Units x 12 va 1320 va Transformer 2 Following are recommend...

Страница 35: ...O C R Y W G O C R Y W G O C R Y W G O C R Y W G O C T STAT MASTER PTAC UNIT 1 UNIT 2 UNIT 3 1 Do not daisy chain R 24 VAC 2 Maximum of 4 PTAC units can be connected to one single wall thermostat 3 Wa...

Страница 36: ...specified on drawing schedule and specifications Part 2 Chassis Description 2 1 General The chassis shall be a factory assembled single piece heating and or cooling unit that is simple to install and...

Страница 37: ...n be easily configured All models shall have a configuration dipswitch easily accessible for the maintenance person optimal comfort settings CONTINUOUS or CYCLE fan mode in HEATING CONTINUOUS or CYCLE...

Страница 38: ...shall have 36 inches of flexible steel conduit and a plug in connector for easy connect disconnect 3 Insulated Polymer Wall Sleeve PN SLEEVE INSUL 1PK shall be made from a molded polymer with factory...

Страница 39: ...force of 10 g s and a random continuous force of 1g during shipping Chassis wall sleeves and grilles shall be shipped in separate cartons Universal handling instructions shall be defined and visible...

Страница 40: ...ctory installed 208 230V 15 amp receptacle Electrical subbase with factory installed 208 230V 20 amp receptacle Electrical subbase with factory installed 208 230V 30 amp receptacle 52C P 17SI SUBBASE...

Страница 41: ...Y ARE EXCLUSIVE AND MAY NOT BE ALTERED ENLARGED OR CHANGED BY ANY DISTRIBUTOR DEALER OR OTHER PERSON WHATSOEVER ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS...

Страница 42: ...DEALER OR THE CARRIER AUTHORIZED SERVICE CENTER HE RECOMMENDS They have been set up to handle the great majority of all possible service problems The quickest surest and best way to get your air condi...

Отзывы: