Table 5 - Fan Performance (Continued)
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
3700
621
0.98
1.06
679
1.15
1.25
734
1.33
1.44
786
1.51
1.64
837
1.70
1.84
4063
665
1.21
1.32
717
1.39
1.51
769
1.58
1.72
818
1.78
1.94
866
1.98
2.15
4375
706
1.48
1.61
757
1.68
1.82
805
1.88
2.04
852
2.09
2.27
897
2.31
2.50
4688
749
1.79
1.95
797
2.00
2.17
843
2.21
2.40
887
2.44
2.65
930
2.67
2.89
5000
793
2.14
2.33
838
2.37
2.58
881
2.60
2.82
923
2.83
3.07
965
3.06
3.33
5313
837
2.55
2.77
880
2.78
3.02
921
3.03
3.29
961
3.26
3.54
1000
3.52
3.82
5700
882
3.00
3.25
922
3.24
3.52
961
3.49
3.79
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
RPM
KWI
BHP
3700
885
1.89
2.05
932
2.09
2.27
978
2.30
2.49
1022
2.50
2.72
4063
912
2.19
2.38
957
2.40
2.61
1001
2.61
2.83
1043
2.83
3.07
4375
941
2.52
2.74
984
2.74
2.98
1026
2.97
3.22
4688
972
2.89
3.14
1013
3.12
3.39
5000
1005
3.31
3.59
1044
3.55
3.85
5313
5700
Normal Font - Field Installed Drive Package
8. Conversion - Bhp to KWI
Legend:
1.2
0.6
0.8
Available External Static Pressure (in. wg)
Bold Font -
Standard Drive P Standard Motor.
Italics Font
-
Medium Drive P Medium Static Motor.
RPM -
Revolutions Per Minute
KWI -
Kilo Watts Input to Motor
BHP -
Brake Horsepower Input to Fan
CFM -
Cubic Feet per Minute
in.wg -
Inch Water Gage
Notes:
1. Do not adjust motor rpm such that motor maximum bhp and/or watts is exceeded at the maximum operatin cfm.
2. Static Pressure (i.e Filters) must be added to external static pressure before entering fan performance table.
3. Interpolation is permissible. Do not extrapolate.
4. Fan performance is based on wet coils, clean filters and casing loses.
5. Extensive motor and drive testing on these units ensures that the full brake horsepower and watts range of the motor can be utilized with confidence. Using your fan motors up to the watts
or bhp rating shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected.
6. Bold data shows the range of air flow rate for unit management system, other rpms require field-supplied drive.
7. Use of field-supplied motor may affect wiring size. Contact your Carrier representative for details.
KWI=
Bhp X 0.746
Motor efficiency
Available External Static Pressure (in. wg)
Air Flow
Rate (CFM)
Air Flow
Rate (CFM)
1.4
1.6
1.8
2.0
Unit 50TCM - D14 - 12.5 Tons - 400V - 50Hz
Unit 50TCM - D14 - 12.5 Tons - 400V - 50Hz (Continued)
0.2
0.4
1.0
Page 31
Содержание 50TCM Series
Страница 6: ... LPHQVLRQV 7 8 85 6 76 0 16 216 7 007 Page 6 ...
Страница 8: ... 85 6 76 0 16 216 7 0 LPHQVLRQV 7 5 5 Page 8 ...
Страница 10: ... LPHQVLRQV 7 85 6 76 0 16 216 7 0 5 5 Page 10 ...
Страница 24: ...Typical Wiring Schematic 50TCMA07 400V Page 24 ...
Страница 25: ...Typical Wiring Schematic 50TCMD08 09 400V Page 25 ...
Страница 26: ...Typical Wiring Schematic 50TCMD12 14 400V Page 26 ...
Страница 27: ...Typical Control Schematic 50TCMA Series Page 27 ...
Страница 28: ...Typical Control Schematic 50TCMD Series Page 28 ...
Страница 32: ...Charging Chart 400V 50Hz 50TCMA07 Charging Chart 400V 50Hz 50TCMD08 CIR 1 Page 32 ...
Страница 33: ...Charging Chart 400V 50Hz 50TCMD08 CIR 2 Charging Chart 400V 50Hz 50TCMD09 CIR 1 Page 33 ...
Страница 34: ...Charging Chart 400V 50Hz 50TCMD09 CIR 2 Charging Chart 400V 50Hz 50TCMD12 CIR 1 Page 34 ...
Страница 35: ...Charging Chart 400V 50Hz 50TCMD12 CIR 2 Charging Chart 400V 50Hz 50TCMD14 CIR 1 Page 35 ...
Страница 36: ...Charging Chart 400V 50Hz 50TCMD14 CIR 2 Page 36 ...