18
–
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
2
3
4
Fan motor
(for indoor)
Room temp. sensor (TA-sensor)
Heat exchanger temp. sensor (TC-sensor)
Louver motor
AFS-220-31-4B
( — )
( — )
MSBPC20F04
AC 220V, 31W
10k
Ω
at 25°C
10k
Ω
at 25°C
Output (Rated) 1W, 16 poles, DC12V
No.
1
2
3
4
5
6
7
8
Parts name
Reactor
Outdoor fan motor
Suction temp. sensor (TS sensor)
Discharge temp. sensor (TD sensor)
Outside air temp. sensor (TO sensor)
Terminal block (
5
P)
Compressor
Coil for PMV
Model name
CH-69-Z-T
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
——
DA131S1B-31FZ
CAM-MD12T
CTH-5
Rating
L = 1
9
mH, 1
0
A
DC140V, 43W
10k
Ω
(25°C)
62k
Ω
(20°C)
10k
Ω
(25°C)
20A, AC250V
3-phases 4-poles 1100W
DC12V
FILE NO. SVM-12052
Parts name Type Specifications
Содержание 39cvur018-703
Страница 94: ...TOSHIBA CARRIER THAILAND CO LTD ...